Kind: Digital Transmitter
Type: AC Transmitter
Phase: Single
Wire-Assembly Type: Four-wire Transmitter
Accuracy Grade: 0.1G
Certification: CE
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Guangdong, China

Basic Info.

Model NO.
JSD TAE-1001D
Customized
Non-Customized
Input
0-1000V/0-500V/0-220V/0-110V/0-20A/0-10A/0-5AAC
Output
0-3.3V/0-5V/0-10V/1-5V/4-20mA/0-20mA
Power
5VDC/12VDC/15VDC/24VDC/9-30VDC/220VAC
High Accuracy
0.1% F.S, 0.2% F.S,
High Isolation Voltage
3000VDC/60s
Wide Operation Temperature
-45~+85
Warranty
3 Years
Transport Package
Bubble Bag+Waterproof Bag
Specification
94*47*25.5mm
Trademark
jieshengda
Origin
Shenzhen
Production Capacity
99999

Product Description

0-5AAC or 0-10AAC to DC 0-10VDC signal isolation transmitter 
MODEL:JSD TAE-1001D Series
1-in-1-out high AC-DC(voltage/Current) signal isolation amplifier isolation transmitter

Quotation is not final sale price, please consult sales manager for details
Features:                                                               
Small size, low cost, PA66 Retardant housing international standards DIN35mm rail mounting
Three-port isolation (input, output and power supply )
High accuracy (0.1% F.S, 0.2% F.S, 0.5% F.S)
High isolation voltage (3000VDC/60S)
Low temperature drift (50PPM/ºC)
Wide operation temperature (-45~+85ºC)
High reliability (MTBF>50 Wan hour)
Power supply (5VDC/12VDC/15VDC/24VDC/9-30VDC/220VAC,etc.)
AC Signal input (0-1000V/0-500V/0-220V/0-110V/0-20A/0-10A/0-5A,etc.)
International standard signal output (0-3.3V/0-5V/0-10V/1-5V/4-20mA/0-20mA,etc.)
Applications:
AC signal acquisition and conversion
AC small signal amplification and conversion
High-precision measurement and monitoring of power distribution
Power isolation monitoring industrial site
Power monitoring, medical equipment isolation barrier
Industrial field signal isolation and distance transmission without distortion
External form a single-phase or poly phase transformer isolation transmitter
General Description:
JieShengda Technology JSD TAE-1001D series 1-in-1-out AC-DC signal isolation transmitter, is an AC signal is collected and converted into a corresponding analog linear DC signal mixing circuit. The isolation transmitter a set of multi-channel micro-power, high isolation DC-DC power supply and a set of high-precision AC-DC signal conversion circuit. The group of high-precision AC-DC circuit can be sensor to the 0-20AAC or 0-1000VAC(50~60Hz) AC signal is converted into a proportional analog voltage to international standards and current signals,(eg:4-20mA/0-20mA/0-5V/1-5V/0-10V) isolation transmitter SMD technology and new quarantine measures to isolate the power supply and the transmitter work input signal/output isolation voltage up to 3000VDC external transformer can be formed after the single-phase or multi-phase transmitter isolation between input and output signals to achieve isolation. Products in power remote monitoring, instrumentation, medical equipment, industrial automation control and other fields widely used. For Two-wire AC to DC signal isolation transmitter Please choose: JSD TAW-1001D-100L-E series;
Sections and Definitions
:
Selections list:
signal input code: Power supply code: output signal code:
Voltage(AC) Current(AC) W: 5-30VDC 1: 4-20mA
1:       0-1V A: 0-20mA 1: 24VDC 2: 0-20mA
2:      0-5V B: 0-100mA 2: 15VDC 3: 0-10mA
3:      0-10V C: 0-500mA 3: 12VDC 4: 0-5V
4:      0-110V D: 0-1000mA 4: 5VDC 5: 0-10V
5: 0-220V E: 0-1500mA 5: 220VAC 6: 1-5V
6: 0-380V F: 0-2000mA     7: 0-3.3V
7:      0-500V G: 0-5000mA        
8:      0-1000V H: 0-10000mA        
U: User-defined U: User-defined U: User-defined
Note: When ordering, please determine input,output and power , special can customize
Selection Example:
Example 1: input:0-500VAC;output:4-20mA;power supply:24VDC;Model: JSD TAE-1001D-711

Example 2: input:0-200VAC;output:0-10V;power supply:15VDC;Model: JSD TAE-1001D-U25

Example 3: input:0-10AAC;output:4-20mA;power supply:220VAC;Model: JSD TAE-1001D-H51

Example 4: input:0-5AAC;output:0-3.3V;power supply:30VDC;Model: JSD TAE-1001D-GW7

Example 5: input:0-1AAC;output:4-20mA;power supply:18VDC;Model: JSD TAE-1001D-DW1

Example 6: input:0-100VAC;output:0-20mA;power supply:5VDC;Model: JSD TAE-1001D-U42
Electrical Characteristics:
Signs Item Test condition Min Type Max Units
Isolation
characteristics
Isolation voltage AC,50Hz,tested for 1 minute, humidity<70% leakage current < 1mA,)   3000   V(rms)
Transmission characteristics Gain   1 50/10 100/20 V(A)/V
Gain drift     ±50   ppm/ºC
Non-linearity   ±0.1 ±0.2   %FSR
Accuracy Class   ±0.1 ±0.2 ±0.5 %
Input characteristics Signal input voltage   1 500 1000 VAC
current   0.1 10 20 AAC
Input impedance Input offset voltage   2 5 7 mV
Output characteristics Signal output voltage   0 10   V
current   0 20   mA
Load capacity voltage Vout=10V   2  
current   0 350 500 Ω
Signal output ripple Unfiltered   10 20 mVRMS
Response time     <300   mS
Power
Supply
input characteristics
DC
Power supply
Voltage   3.3 12 30 VDC
Power   1 1.2   W
Range   -10   +10 %
AC
Power supply
Voltage   90 220 260 VAC
Power   0.8 1   W
Range   - - - %
Other characteristic operating temperature   -45   85 ºC
storage temperature   -55   105 ºC
weight   75   85 g
Note: normal load≤350Ω,if requiring load is 500Ω, Please note when ordering
Pins function description:
Pin Function Description Pin Function Description Package
1 Signal In+ 5 Signal Out+ International Standard
DIN35 Rail Mounting
2 Signal In- 6 Signal Out-
3 No pin (NC) 7 Power In + / AC L
4 No pin (NC) 8 Power In - / AC N
Application Wiring Diagram:
0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter
 

Please pay attention to safety when wiring input terminal
0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter
Notes
:

1,Please read the user manual carefully before using. If any question please contact our technical support department.
2,Please do not use this product in hazardous area.
3,NC" pin must not be connected to any external circuit, otherwise it will damage the product itself;
4,Calculating from the date of delivery, during normal use of the product, any quality problems are free repair or replacement by Company during 3 years warranty;
5,the product is strictly forbidden demolish without permission for not damage;
6,All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
7,In this datasheet, all the test methods of indications are based on corporate standards.
Copyright:
Copyright © 2018 Shenzhen Jieshengda Technology Co., Ltd.
Without the prior written permission of the company, any content in this manual may not be copied, distributed, translated or transmitted in any form or method (electronic or mechanical).
Including photocopying, recording or storage in any information storage and retrieval system. This manual is subject to modification or update without notice.
trademark
All other trademarks and copyrights belong to their respective owners
0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter0-5AAC or 0-10AAC to DC 0-10V Signal Isolation Transmitter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now