Kind: Two-wire Transmitter
Type: DC Transmitter
Phase: Single
Wire-Assembly Type: Two-wire Transmitter
Accuracy Grade: 0.1G
Certification: CE
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Guangdong, China

Basic Info.

Model NO.
JSD TAW-1001D-100L
Customized
Non-Customized
Input
4-20mA/0-20mA
Output
0-20mA/4-20mA
Isolation Voltage
3000VDC
Operating Temperature
-45~+85
Gain Drift
50ppm
Non-Linearity
0.2
Transport Package
Bubble Bag+Waterproof Bag
Specification
94*25*41mm
Trademark
jieshengda
Origin
Shenzhen
Production Capacity
99999

Product Description

two-wire 4-20mA to 4-20mA isolation transmitter
1-input-1-output passive two-wire 4-20mA isolation transmitter

Quotation is not final sale price, please consult sales manager for details
MODEL:JSD TAW-1001D-100L
https://jieshengdakj.en.made-in-china.com/product-list-1.html


Features:
Small size, low cost, No correction directly use
Two-port isolation(input, output)
1-input-1-output
High accuracy(0.1% F.S, 0.2% F.S)
High linearity(0.1% F.S)
High isolation voltage(3000VDC/60S)
Low temperature drift(35PPM/ºC)
Low impedance(voltage drop <3V, 20mA)
Wide Industrial class operation temperature(-45~+85ºC)
Wide voltage input (7.5V-32V)
High reliability (MTBF>50 Wan hour)
Passed CE Certificate
International standard signal input and output(4-20mA/0-20mA)

Application:
DC current/voltage signal isolation, conversion and amplification
Analog signal ground interference suppression and analog isolation, acquisition
4-20mA/0-20mA sensor signal isolation, transformation and signal distribution conversion
Instrumentation and sensor signal transceiver
Two-wire primary/secondary instrumentation signal acquisition and isolation
Power isolation monitoring industrial site
Analog signal data isolation, acquisition, conversion, and distance transmission
Industrial field signal isolation and conversion, and distance transmission without distortion
Power monitoring, medical equipment isolation barrier
Overcome inverter, large motors, power equipment, acquisition systems, DCS and PLC Field interference
General Description:
JIE Sheng Da Technology DIN35 1x1 MI 4-20mA two-wire passive single-channel analog signal isolation transmitter is a signal conditioner with electrical insulation between input and output, it can receive a variety of analog signal from the field instrument, and transmit a standard output signal or user-specified special signal to the control room,PLC,PC or DCS system. The product is isolated between input and output , the isolated voltage is up to 3000VDC .It is widely used in the industrial measurement systems, medical electronic equipment, electrical equipment etc. Adopting high efficiency electromagnetism isolation technology to achieve signal isolation, it is available to keep high output accuracy, good linearity and low temperature drift. For dual-channel isolation transmitter please choose DIN35 2*2 MI 4-20mA series.
Product Selection Parameter List:
Product Selection Parameter List:   
DIN35 1x1 MI 4-20mA Detailed description
Package Marking Code       Standard DIN35 rail mounting
Channel code     1-input-1-output
Isolation code   Magnetic Isolation Products
current signal Input 4-20mA current signal input
current signal output 4-20mA current signal output
Selection Example:

Example 1: Signal input 1:4-20mA; signal output 1:4-20mA; Model: DIN35 1x1 MI 4-20mA

Example 2: Signal input 1:0-20mA; signal output 1:0-20mA; Model: DIN35 1x1 MI 4-20mA


Electrical Characteristics:
Signs Item Test Condition Min Typ. Max Units
Isolation
characteristics
Isolation voltage AC,50Hz,(Tested for 1 minute humidity<70% ,leakage current< 1mA,)   3000   V(rms)
Insulation resistance 500VDC(input/output)   100  



Transmission characteristics
Gain drift     ±35   ppm/ºC
Non-linearity     ±0.1 ±0.2 %FSR
Input current   4 20 30 mA
Output oououtoutput current   4   20 mA
Load capacity current RL≤(Us-5)/0.02
Us: Loop power supply voltage
  250   Ω
Frequency Response small-signal band width,Io=20mA   50   Hz
Signal output ripple     5 10 mVRMS
Power input characteristics Power supply voltage   ―― ―― ―― VDC
Power loss   ―― ―― ―― W
Range   ―― ―― ―― %
operating temperature   -45   85 ºC
storage temperature   -55   105 ºC
weight     60   g
size 94.5*25.5*41 mm
Note  Normal load ≤ 300Ω

Pin Function Description:
Outputting types Pin Function Pin Function Storage
Single channel
passive 4-20mA current output
1 Signal input + 5 NO PIN(NC) Standard DIN35 rail mounting
2 Signal input - 6 NO PIN(NC)
3 NO PIN(NC) 7 Signal output +
4 NO PIN(NC) 8 Signal output -

  Wiring application diagram:
Two-Wire 4-20mA to 4-20mA Isolation Transmitter

Two-Wire 4-20mA to 4-20mA Isolation Transmitter
 
Two-Wire 4-20mA to 4-20mA Isolation TransmitterTwo-Wire 4-20mA to 4-20mA Isolation TransmitterTwo-Wire 4-20mA to 4-20mA Isolation Transmitter
 
Two-Wire 4-20mA to 4-20mA Isolation TransmitterTwo-Wire 4-20mA to 4-20mA Isolation Transmitter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now