RS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a Converter

Product Details
Customization: Available
Kind: New-Type Transmitter
Type: DC Transmitter
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • RS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a Converter
  • RS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a Converter
  • RS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a Converter
  • RS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a Converter
  • RS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a Converter
  • RS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a Converter
Find Similar Products

Basic Info.

Model NO.
JSD DA-A02-RS232/485-I4
Customized
Non-Customized
Input
0-5V/0-10V/1-5V/0-10mA/0-20mA /4-20mA/2-10V/0-3.3V
Output
RS-485/RS-232
Power
5V/12V/15V/24V/9-36VDC
High Accuracy
(0.1% F.S, 0.2% F.S)
High Isolation Voltage
(3000VDC/60s)
Operation Temperature
-45-+85
Transport Package
Bubble Bag+Waterproof Bag
Specification
107*79 * 25m
Trademark
jieshengda
Origin
Shenzhen
Production Capacity
99999

Product Description

RS232/RS485 digital signal to analog 4-20mA signal isolation D/A converter
 Quotation is not final sale price, please consult sales manager for details
Shenzhen JieShengdaTechnology Co., Ltd.
Are there any special products that can be customized and developed
MODEL:JSD DA-A02
Exhibition hall: https://jieshengdakj.en.made-in-china.com/


RS232/RS485 digital signal to analog signal isolation D/A converter
Features:
Low cost, small size modular design
RS-485/232 Interface, Analog signal acquisition, isolated output
Output accuracy>0.2%
Can be remotely reconfigured for modules accuracy
Three-port isolation (input/output/power supply): 3000VDC /60s
Wide operating power supply: 8 ~ 32VDC
High reliability, easy programming and installation
International standard DIN35mm rail mounting for easy centralized wiring
Can Program setting module address, baud rate , etc.
Can set the host to read the JSD DA-A02 data to achieve remote acquisition
Supports Modbus RTU
Applications:                               
RS-232/485 bus industrial automation control systems
Industrial control signal isolation and long-term transmission
Equipment operation Commissioning and control
The sensor signal remote transmission and signal reduction
Industrial field actuator data given
Medical, industrial product development
Intelligent building control, security engineering and other applications
Standard analog signal output
4-20mA signal output

General Description:
                   
JSD DA-A02 series realize host RS-485/232 interface signal isolation converted into a standard analog signal, to control the remote device. JSD DA-A02 products can be applied to RS-232/485 bus industrial automation control system,4-20mA /0-5V/0-10V standard signal output, to control industrial site execution set equipment, control equipment and display instrument. Products include power supply isolation, signal isolation, linearization, D/A conversion and RS-485 serial communication. Each serial interface can connect up to 256 pieces JSD DA-A02 Series modules, communication using ASCII code or MODBUS RTU communication protocol, and its instruction set compatible with the ADAM modules, baud rate can been set by the code, with other manufacturers control module hang in the same RS-485 bus for easy programming.
JSD DA-A02 series products are based on SCM's intelligent monitoring and control system, users set the calibration value, address, baud rate, data format, checksum status, and configuration information are all stored in nonvolatile memory EEPROM.
JSD DA-A02 products are according to industry standard design, isolation between signal output / communication interface, can withstand voltage 3000VDC, high anti-interference ability and reliability. Operating temperature range is - 45 ~ +85°C.
Function Description:
JSD DA-A02 signal isolation D / A converter module can be used to output one channel voltage or current signal, can also be used to output two common ground current or voltage signal.
1. Analog signal output 12-Bit acquisition accuracy, all products signal input range have been calibrated. In use, users also can program calibration easily. About the specific current or voltage input range, please see product selection. when need two channels signal output, signal value must be the same.
2. Communication protocol
Communication Interface: one channel standard RS-485 communication interface, or one standard RS-232 communication interface, specify when ordering.
Communication Protocols: supports two protocols, characters protocol of the command set defined and MODBUS RTU communication protocol. Can be programmed using the kind of communication protocol, can be achieved with PLC, RTU of many Brands or computer monitoring system for network communication.
Data Format: 10 Bits. 1 start bit, 8 data bits, 1 stop bit.
Address: (0 to 255) and baud rate (2400, 4800, 9600, 19200, 38400 bps) can be set, the most long-distance about communication networks is up to 1200 meters, through the twisted-pair shielded cable. Communication interface of high anti-jamming design, ± 15KV ESD protection, communication response time is less than 100mS.
3. Anti-jamming
According to need to set the checksum. Module internal has transient suppression diodes, can inhibit a variety of surge pulse, protection module, and internal digital filter can also be well suppressed from the grid frequency interference.

Sample 1: Model:JSD DA-A02-485-IO4   RS-485 Interface,4-20mA signal output
Sample 2: Model:JSD DA-A02-232-VO1  RS-232 Interface,0-5V signal output

JSD DA-A02 General parameters:
(typical @ +25 ºC, Vs to 24VDC)
Output type: current / voltage signal
Accuracy: 0.2%
Output maladjustment: current output ± 0.5 uA / ° C, voltage output of ± 0.1 mV / ° C
Temperature drift:± 20 ppm / ºC (± 30 ppm / ºC, maximum)
Output load capacity: current output 350Ω (4-20mA/0-20mA/0- ± 20mA current output)
voltage output 10mA (0-5V/0-10V/0- ± 5V voltage output)
Communication: RS-485 protocol or RS-232 standard characters protocols and MODBUS RTU communication protocol
Baud Rate (1200,2400,4800,9600,19200,38400 bps) can be selected via software
Address (0 to 255) can be selected via software
Communication Response Time: 100 ms maximum
Power Supply: +8 ~ 32VDC wide range power supply, internal anti-reverse and over-voltage protection circuit
Power Loss: less than 1.5W
Operating Temperature: - 45 ~ +80 ºC
Humidity: 10 ~ 90% (no condensation)
Storage Temperature: - 45 ~ +80 ºC
Storage Humidity: 10 ~ 95% (no condensation)
Isolation Voltage: communication interface / output: 3KVDC, 1 minute, leakage current:1mA
Which communication interface and power supply are common ground.
Shock Voltage: 3KVAC, 1.2/50us (peak)
Dimensions: 106.7 mm x 79 mm x 25mm
Pin function:                                                                                        
Pin Name Description Pin Name Description
1 PW+ Power+ 7 Out0+ Analog signal output 0+
2 GND Power- 8 GND1 Analog signal output 0-
3 INIT Initialization state set 9 NC NO PIN
4 D+ RS-485 Signal+ 10 Out1+ Analog signal output 1+
5 D- RS-485 Signal- 11 GND1- Analog signal output 1-
6 GND Power-,Output port ground 12 NC NO PIN
Initialization JSD DA-A02 modules:
All JSD DA-A02 modules, if you use RS-485 network, must be assigned a unique address code, address code value of hexadecimal numbers between 00 and FF. However, all new JSD DA-A02 modules use one factory initial settings, as follows:
Address code: 01
Baud rate: 9600 bps
Checksum is forbidden
As the new module address codes are the same, their address will be contradictory to other modules, so when you set up the system, you must reconfigure each JSD DA-A02 module address. JSD DA-A02 module can be connected the power cord and RS485 communication lines, through configuration commands to modify the JSD DA-A02 module address. Baud rate, parity and status, communication protocols also need to be adjusted according to user requirements. In the modified baud rate, parity and status, communication protocol, you must first enter the module to the default state, or can't be modified.
Let the module into the default state:
JSD DA-A02 module has a special INIT pin. Connecting the INIT PIN to ground (GND PIN), then open power, the module into the default state. In this state, the module is configured as follows:
Address code 00
9600 bps baud rate
Checksum is forbidden, At this time, via configuration commands you can modify the JSD DA-A02 module baud rate, parity, checksum state and other parameters, by setting the module communication protocol command to select the communication protocol. When are not sure a module specific configuration, can also be configured by installing the jumper, so that the module into the default state, then reconfigure the module. If clients need set the module to MODBUS RTU communication protocol, see the MODBUS protocol section for instructions.
JSD DA-A02 character protocol command set:
Order is by a series of characters, such as first code, address ID, variables, an optional checksum byte and a terminator (c r) which can show command. In addition to wildcard address "**"synchronization command, the host only commands a JSD DA-A02 module once.
Command format: (Leading Code) (Addr) (Command) [data] [checksum] (c r)
(Leading code) prefix is the first letter of the command. All commands require a command prefix, such as %,$,#,@,...
etc. 1 - Character
( Addr ) module address code, if not specified below, range is from 00 ~ FF (hexadecimal). 2 - Character
(Command) shows the command code or variable values. Variable length
[Data] some output command needs data Variable length
[Checksum] brackets Checksum (checksum) shows an optional parameter, only the checksum is enabled, need this option. 2 - Character (Cr) a control code character as identify, (c r) as a carriage return character, its value is 0x0D. 1 - Character When enabled checksum (checksum), users need [Checksum]. It accounted for 2 - character. Commands and responses must be attached checksum feature. Checksum used to check all input commands to help you find the host to the module command module to the host response to errors and mistakes. Checksum characters placed in command or in response to the character after the carriage return before. Calculated as follows: two characters, the hexadecimal number for all issued prior to the ASCII values of and, then with hexadecimal digits 0xFF phase proceeds.
Examples: Disable checksum (checksum)
Command: $002(cr)
Response:!00020600 (cr)
Enable checksum
command: $002B6 (cr)
response: !00020600 A9 (cr)
'$' = 0x24 '0' = 0x30 '2' = 0x32
B6=(0x24+0x30+0x30+0x32) AND 0xFF
'!' = 0x21 '0' = 0x30 '2' = 0x32 '6' = 0x36
A9=(0x21+0x30+0x30+0x30+0x32+0x30+0x36+0x30+0x30) AND 0xFF
Command response:
Response message depends on a variety of commands. Response also is consists of several characters, includes
leading code, variables and end tags. The first code of response signal has two:'!' Or '>' indicates that a valid command
and '?' means invalid. By checking the response information, you can monitor whether the command is valid
Note:
1. In some cases, many commands use the same command format. To ensure that you use a command in the address is correct, if you use the wrong address and this address represents another module, then the command will take effect
in another module, resulting in an error.
2. the command must be entered in uppercase letters.
1,Set Channel N Analog Output Value Command
Description: set analog output module channel N output value
Command Format:#AAN(data)(cr)
Parameter:# delimiter character
AA module address, (range 00-FF). Factory address is 01, converted to hexadecimal ASCII code for each
character. Such as address 01 into hexadecimal are 30H and 31H.
N Channel code 0 or 1.Change to hexadecimal are 30H and 31H
(data) set channel N reset output analog value .The data format is in Engineering Units,Percent of FSR,
Two's complement hexadecimal. Refer to Chapter 3 Command Set.
(cr) is the terminating character, carriage return (0Dh)
Response : >(cr) command is valid.
?AA(cr) invalid command or illegal operation
Parameter: > delimiter character
(cr) terminating character, carriage return (0Dh)
There is no response if the format error or communication error or address does not exist.
Example: Command(Character format) #010+16.000(cr)
(Hexadecimal format) 233031302B31362E3030300D
Response (Character format) >(cr)
(Hexadecimal format) 3E0D
The channel 0 output value is +16.000mA at setting address 01H module.
2,Set Channel N Reset Analog Output Value Command
Description:Set Channel N Reset Analog Output Value as the present data formats.
Command Format:#AASN(data)(cr)
Parameter: # delimiter character
AA module address (range 00-FF) hexadecimal. Factory address is 01, converted to hexadecimal ASCII
code for each character. Such as address 01 into hexadecimal are 30H and 31H.
S set reset analog output value
N Channel code 0 or 1. Change to hexadecimal is 30H and 31H
(data) set channel N reset output analog value .The data format is in Engineering Units ,Percent of FSR,
Two's complement hexadecimal. Refer to Chapter 3 Command Set.
(cr) is the terminating character, carriage return (0Dh)
Response : >(c r) command is valid.
?AA(c r) invalid command or illegal operation
There is no response if the format error or communication error or address does not exist.
Example: Command #01S0+04.000(c r)
Response >(c r)
The channel 0 reset output value is +04.000mA at setting address 01H module.
3,Set Analog Output Module Command
Description: Set address, output ranges, baud rate, data formats, checksum and state for an analog output module,
counter data is stored in a EEPROM.
Command Format: %AANNTTCCFF(c r)
Parameter : % delimiter character
AA module address, (range 00-FF) hexadecimal. Factory address is 01, converted to hexadecimal
ASCII code for each character. Such as address 01 into hexadecimal are 30H and 31H.
NN indicates new module hexadecimal address, value NN range is 00~FF
TT hexadecimal indicates type code. JSD DA-A02 must been set 00
CC Baud Rate code (hexadecimal)
Baud rate code Baud rate
04 2400 baud
05 4800 baud
06 9600 baud
07 19200 baud
08 38400 baud
            
                   Table 2 Baud rate code
         FF    Hexadecimal 8-bit represents the data format, checksum. Note: from bits2 to bits5 need not been set to zero.
 
Bit7 Bit 6 Bit 5 Bit 4 Bit 3 Bit2 Bit 1 Bit 0
          
          Table 3   Data format, checksum and code                 
Bit7:Reserved bits (must set to 0)                                 
                  Bit6:Checksum states, if 0: Disabled, if 1: Enabled                 
Bit5-bit2:Not use (must set to 0)
                  Bit1-bit0:Data Format Bit
                            00:Engineering Units
                            01:% of FSR
                            10:Twos complement
                            11:Ohms (only for RTD products ) 
(c r) terminating character, carriage return (0Dh)
Response:!AA(c r) command is valid
? AA(c r) command is invalid or illegal operation, or do not set up line before changing baud rate or checksum
Parameter Description:
! delimiter character which indicates a valid command.
? delimiter character which indicates an invalid command.
AA represents input module address
(c r) terminating character, carriage return (0Dh)
If you configure module for the first time, AA=00 and NN equal to new address. If reconfigure module changing address, input range, data formats, AA equals to present configured address, NN equals to the current or new address. If reconfigure module changing baud rate or checksum state, must install command string, make them in listening mode, module address is 00H, also AA=00H, NN=present or new address.
There is no response if the format error or communication error or address does not exist.
Example: command %0011000600(c r)
Response! 11 (c r)
Description: % delimiter character
00 indicates analog output JSD DA-A02 module original address set to 00H.
11 indicates new module hexadecimal address is 11H
00 indicates type code, JSD DA-A02 must been set to 00
06 indicates baud rate: 9600 baud
00 indicates data format is Engineering Units,checksum is disabled
4,Read Set Status Command
Description: Read configuration for a specified JSD DA-A02 module.
Command Format: $AA2 (c r)
Parameter: $ delimiter character
AA module address, (range 00-FF) represents the 2-character hexadecimal
2 indicates read set state command
(c r) terminating character, carriage return (0Dh)
Response:! AATTCCFF(c r) command is valid
?AA(c r) command is invalid or illegal operation
Parameter:! delimiter character
AA represents input module address
TT Type Code
CC Baud rate code, Table 3
FF Table 4
(c r) terminating character, carriage return (0Dh)
There is no response if the format error or communication error or address does not exist.
Example: command $302(c r)
response !300F0600(c r)
! delimiter character
30 indicates JSD DA-A02 module address is 30H
00 indicates input type code
06 represents that baud rate is 9600 baud
00 represents that data format is Engineering Units, disable checksum
5,Offset Calibration Command
Description: Calibrates an analog output module ZERO offset errors
Command Format: $AA1N (c r)
Parameter: $ delimiter character
AA module address, (range 00-FF) represents the 2-character hexadecimal
1 represents offset calibration command
N channel code 0~1
(c r) terminating character, carriage return (0Dh)
Response: ! AA (c r) command is valid
?AA(c r) command is invalid or illegal operation
Parameter: ! delimiter character which indicates a valid command.
? delimiter character which indicates an invalid command.
AA represents input module address
(Module Name) JSD AD11, JSD DA-A02 or JSD 81 or other module name
(cr) terminating character, carriage return (0Dh)
There is no response if the format error or communication error or address does not exist.
Example: command $08M(c r)
Response !08 JSD DA-A02 (c r)
At address 08H module is JSD DA-A02
8,Channel N Analog Output Value Read-Back Command
Description: Analog output module channel N output value read-back
Command Format: $AADN(c r)
Parameter: $ delimiter character
AA module address, (range 00-FF) represents the 2-character hexadecimal
D analog output value read-back command
N channel code 0~1
(c r) terminating character, carriage return (0Dh)
Response: !AA(Data)(c r) command is valid
?AA(c r) command is invalid or illegal operation
Parameter: ! delimiter character
AA represents input module address(range 00-FF)
(Data) read-back channel N analog output data. Data format may be engineering units, the percentage of FSR, Hexadecimal complement. Detailed description see command 3.
(cr) terminating character, carriage return (0DH)
There is no response if the format error or communication error or address does not exist.
Example: command $01D0 (c r)
Response !01+12.000 (c r)
At address 01H, module channel 0 current output value is +12.000mA (Data format is engineering units)
9,Set Communication Protocol Command
Description: Set the module communication protocol to characters protocol or Modbus RTU protocol.
Command Format: $AAPV(c r)
Parameter: $ delimiter character
AA module address, (range 00-FF) represents the 2-character hexadecimal
P set communication protocol command
V protocol code: 0 or 1. Change to hexadecimal is 30H or 31H.
0:Characters protocol
1:Modbus RTU protocol
(c r) terminating character, carriage return (0Dh)
Response: !AA(c r) command is valid
?AA(c r) command is invalid or illegal operation
Parameter: ! delimiter character which indicates a valid command.
? delimiter character which indicates an invalid command.
AA represents output module address
(c r) terminating character, carriage return (0Dh)
There is no response if the format error or communication error or address does not exist.
Set command protocol must be effective by default.

Example 1: command $00P1(c r)
response !00 (c r)
Setting the communication protocol is Modbus RTU protocol.
Example 2: command $00P0(c r)
response !00 (c r)
Setting the communication protocol is characters protocol
Output Range and Data Format:
JSD DA-A02uses three data formats:  00:Engineering Units
01:% of FSR
10:Twos complement hexadecimal
Table 4 Output Range and Data Format
Example:
1. Output Range is A4:4-20mA, setting output is 4mA:
Engineering Units user command #010+04.000(c r)
Percent of FSR user command #010+020.00(c r)
Twos complement user command #010333(c r)
2. Output Range is U1:0-5V, setting output is 3V:
Engineering Units user command #010+3.0000(c r)
Percent of FSR user command #010+060.00(c r)
Twos complement user command #010999(c r)
         
Input range Data format Max Min
IO1:4-20mA Engineering Units +20.000 +04.000
% of FSR +100.00 +020.00
Twos complement hexadecimal FFF 333
IO2:0-20mA Engineering Units +20.000 ±00.000
% of FSR +100.00 ±000.00
Twos complement hexadecimal FFF 000
VO1:0-5V Engineering Units +5.0000 ±0.0000
% of FSR +100.00 ±000.00
Twos complement hexadecimal FFF 000
VO2:0-10V Engineering Units +10.000 ±00.000
% of FSR +100.00 ±000.00
Twos complement hexadecimal FFF 000
VO5:0-±5V Engineering Units +5.0000 -5.0000
% of FSR +100.00 -100.00
Twos complement hexadecimal FFF 000
VOud:/IOud: User-defined Engineering Units +100.00 ±000.00
% of FSR +100.00 ±000.00
Twos complement hexadecimal FFF 000
IO7:0-±20mA Engineering Units +20.000 -20.000
% of FSR +100.00 -100.00
Twos complement hexadecimal FFF 000
VO6:0-±10V Engineering Units +10.000 -10.000
% of FSR +100.00 -100.00
Twos complement hexadecimal FFF 000
Module Calibration:
We have calibrated the module, the user can use directly.
You can also use the product calibration function to re-calibrate the module. During calibration, the module needs
using a precision multi-meter to monitor the output value.
In order to improve calibration accuracy, it is recommended to calibrate using the following equipment:
1. A five and a half or more high-precision voltage / current measuring instruments to monitor the accuracy of the
output signal
Calibration:
1. Select to need been calibrated output channel, in accordance with the module output scope connects to the
corresponding voltage or current measuring instruments.
2. Set output zero signal, usually is 0mA, 4mA or 0V. Set the analog output by the first command of command sets,
adjusted to the output signal is zero value which the measuring instruments display.
3. Until the signal stabilized, send the offset calibration $ AA1N command to WJ31 module.(N: channel code 0 or 1)
4. Set output full- scale signal. Set the analog output by the first command of command sets, adjusted to the output
signal is full- scale value which the measuring instruments display.
5. Until the signal stabilized, send the offset calibration $ AA0N command to WJ31 module.(N: channel code 0 or 1)
6. Finished
Modbus RTU communication protocol:
Module default protocol is character communications protocol. If you need to set the module to Modbus RTU protocol,
please follow these settings:
1. Short connect INIT pin (pin 3) and GND pin (pin 6).
2. Connect the power cord and the communication interface cable.
3. Turn on the power, the module enters the default state automatically, address 00, baud rate 9600.
4. Wait 1 minute, module is initialization.
5. Send the command $00P1(c r), check the response, if is !00 (c r), set successfully.
6. Turn off the power, disconnect the INIT and GND connections.
7. The module has been set to the Modbus RTU protocol mode successfully.
Register Description:
Address 4X Data Property Data Explanation
40001 Out0(0x0000-0x0FFF) read/write channel 0 analog output value
40002 Out1(0x0000-0x0FFF) read/write channel 1 analog output value
40003 Sout0 (0x0000-0x0FFF) read/write channel 0 analog output value after power
40004 Sout1 (0x0000-0x0FFF) read/write channel 0 analog output value after power

Notes:
1,NC pin must not be connected to any external circuit, otherwise it will damage the product itself;
2,Please read the user manual carefully before using. If any question please contact our technical support department.
3,Please do not use this product in hazardous area. The power supply of this product should be DC power source. It is forbidden to use 220VAC power supply.
4,Calculating from the date of delivery, during normal use of the product, any quality problems are free repair or replacement by Company during 3 years warranty
5,the product is strictly forbidden demolish without permission for not damage 
6,All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
7,In this datasheet, all the test methods of indications are based on corporate standards.
Jieshengda Technology (JSD Technology) Introduction:
Shenzhen Jieshengda Technology Co., Ltd. is a high-tech enterprise that integrates research, development, production, and trade. The company specializes in AC-DC power modules, DC-DC power modules, micro power DC-DC module power supplies, medium power modules, high-voltage module power supplies, two wire 4-20mA isolation amplifier modules, isolation amplifiers, mV small signal isolation amplifiers, differential (pressure, tension, gravity) strain bridge signal isolation amplifiers Isolation transmitter, two wire 4-20mA isolation transmitter, RTD Pt100 thermal resistance signal isolation transmitter, thermocouple temperature isolation transmitter, AC voltage and current (electricity) signal isolation transmitter, NTC thermal resistance signal isolation transmitter, absolute value isolation transmitter, frequency pulse signal converter (V/F frequency pulse converter, F/V frequency pulse converter), differential (pressure, tension, gravity) strain bridge signal isolation transmitter Speed sensor signal isolation transmitter, high voltage and high current signal isolation transmitter, isolation power drive transmitter (current and voltage signal amplification), resistance (potentiometer/potentiometer/electronic ruler) displacement signal isolation transmitter, milliohm (mR) resistance signal isolation transmitter, PWM pulse width signal isolation transmitter (analog to PWM pulse signal, PWM pulse width signal to analog signal) A high-tech enterprise that automatically selects isolation transmitters and programmable analog isolation transmitters (which can replace foreign multi signal inputs), and develops, produces, and sells isolation transmitter products such as relays, thermal resistance signal relays, thermocouple relays, RS-485 relays, non isolation amplifiers, and data acquisition modules (A/D data acquisition, D/A data acquisition). The entire series of products have passed CE and RoHS certifications, and the company has passed ISO9001 quality management system certification. Our self-developed products comply with international standards and are compatible with the vast majority of well-known brands both domestically and internationally. Our product range covers thousands of different types, making us one of the manufacturers of analog and digital signal hybrid integrated circuits in industrial automation and industrial control automation.
 The company has passed ISO9001 quality management system certification. The products developed by ourselves are in line with international standards and are compatible with most famous brands at home and abroad. The product types cover more than thousands. It is the simulation of industrial automation and industrial automation. One of the manufacturers of hybrid ICs for signal and digital signals.
Since its inception, Jieshengda Technology has focused on high-end technology application research and development of sensor, isolator transmitter analog signal acquisition, isolation amplification and transformation, and current state-developed rail transit, national grid transformation, wind energy solar power generation, Emerging industries such as electric vehicles are in great demand for matching key electronic components. Through the unremitting efforts of all Jieshengda people, the products have been successfully applied in aerospace control, atomic energy research and development institutions, power, communication, instrumentation, industrial measurement systems, medical equipment, industrial control intelligence, automotive intelligence, intelligent building control, automotive electronics. , security, environmental protection, food, heating and cooling air conditioning systems, water treatment, petrochemical, coal mining, metallurgy, ships and many other fields have been widely used. Under the premise of ensuring quality and reasonable cost performance, we provide products with different functions to customers in different fields. When customers need special products, they can customize related products for customers, provide satisfactory and reasonable solutions for customers, and get favorable comments from customers.
The company has established a "people-oriented, customer first, forge ahead, and common development" business purposes, with "integrity, pragmatism, dedication, innovation" as the management philosophy, the company relies on science and technology for development, and constantly provide users with satisfactory high-tech products, It is the constant pursuit of all Jieshengda people.
Today, Jieshengda people pursue the policy of "aggressive and realistic, rigorous and united", and constantly develop and innovate. "Technology as the core, quality as the life, and action to prove" will provide you with cost-effective products and provide you with The most professional one-stop after-sales service.
Advantage:
The company has R&D talents specialized in the industry for more than ten years, and cooperates with many universities and research institutes. The production cycle is short, the delivery time is fast, the price is more reasonable, and the modular (IC package) design has high integration. The products have passed CE certification and RoHS certification, the company has passed ISO9001 quality management system certification, and can also customize special products for customers.

Products List
AC-DC converter series:
JSD Ax-DxS(D)220   (International standard DIP packaging)
JSD DAx-xxS(D)220  (International standard DIN35 rail mounting)

DC-DC converter series:
Rated voltage input series:
AxxxxS(D)-xW      Rated voltage Input isolated unregulated positive & negative voltage output series
BxxxxS(D)-xW      Rated voltage Input isolated unregulated positive voltage output  
BxxxxM-xW        Rated voltage Input isolated unregulated positive voltage output
BxxxxLS(D)-xW     Rated voltage Input isolated unregulated positive voltage output 
DxxxxS(D)-xW      Rated voltage input isolated unregulated positive voltage dual output 
ExxxxS(D)-xW      Rated voltage Input isolated unregulated positive& negative voltage output
FxxxxS(D)-xW      Rated voltage Input isolated unregulated positive voltage output
GxxxxS-xW        Rated voltage Input isolated unregulated positive & negative voltage output
HxxxxS-xW        Rated voltage Input isolated unregulated positive voltage output
BxxxxULP        Rated voltage input unregulated isolated ultra-low power positive voltage output series

High voltage module power supply series: (input range: 2:1)
HVMDx-xxSxx    Wide-range Voltage Input Non-Isolated Regulated High Voltage Single Output
HVMLDx-xxSxx   Wide- range Voltage Input Non-Isolated Regulated High Voltage Single Output

High voltage module power supply series: (input range: 2:1)
HVMDx-xxSxx     Wide- range Voltage Input Non-Isolated Regulated High Voltage Single Output
HVMLDx-xxSxx    Wide- range Voltage Input Non-Isolated Regulated High Voltage Single Output

Regulated Voltage Output:(input range: ±5%)
IAxxxxS-xW        Rated voltage Input isolated regulated positive& negative voltage output
IBxxxxLS(D)-xW    Rated voltage Input isolated regulated positive voltage output
IExxxxS-xW        Rated voltage Input isolated regulated positive& negative voltage output
IFxxxxS-xW        Rated voltage Input isolated regulated positive voltage output

Regulated Voltage Output Series:( input range: ±10%)
VAxxxxS-xW       Rated voltage Input isolated regulated positive& negative voltage output
VBxxxxLS(D)-xW   Rated voltage Input isolated regulated positive voltage output
VExxxxS-xW       Rated voltage Input isolated regulated positive& negative voltage output
VFxxxxS-xW       Rated voltage Input isolated regulated positive voltage output

 Regulated Voltage Output Series:( input range: 2:1)
WRAxxxxD-xW    2:1 Wide- range Voltage Input Isolated Regulated positive Voltage Output
WRBxxxxD-xW    2:1 Wide- range Voltage Input Isolated Regulated positive Voltage Output
WRAxxxxLD-xW   2:1 Wide- range Voltage Input Isolated Regulated positive& negative Voltage Output
WRBxxxxLD-xW   2:1 Wide- range Voltage Input Isolated Regulated positive Voltage Output

Regulated Voltage Output Series:( input range: 4:1)
URAxxxxD-xW    4:1 Wide- range Voltage Input Isolated Regulated positive& negative Voltage Output
URBxxxxD-xW    4:1 Wide- range Voltage Input Isolated Regulated positive Voltage Output

Isolation Amplifier 
JSD TAW-100L          Two-wire analog passive 4-20mA isolation amplifier
JSD TAW-100L-F        Two-wire analog passive 4-20mA input loop isolation distributor
JSD TAW-100L-P        Two-wire analog passive 4-20mA output loop power supply isolation amplifier
JSD OI-V(I)x-Px-V(I)Ox  Analog Signal Isolation Amplifier (Optical Isolation Series)
JSD TA-101L           Analog Signal Isolation Amplifier (New)
JSD MI-V(I)x-Px-V(I)Ox  Positive&negative signal isolation amplifier (magnetic isolation series)
JSD TAM-101L          Analog Signal Isolation Amplifier (New)
JSD OI-MSx-Px-V(I)Ox   Analog mV Signal Isolation Amplifier (Optical Isolation Series)
JSD TAMS-101L         Analog mV Signal Isolation Amplifier (SIP12,New)
JSD OI-Bx-Px-V(I)Ox     Differential signal isolation amplifier(strain bridge, pressure, tension, gravity) s
JSD NI-V(I)x-Px-V(I)Ox   Analog Signal Non-Isolated Amplifier
JSD TAN-101L           Analog Signal Non-Isolated Amplifier (New)

Isolation Transmitter (magnetic& Optical Isolation Passive Series)
1, Magnetic isolation
Passive series (conventional, loop power supply, output loop power supply, voltage input and output two-wire loop power supply)
A, Regular Two-wire
JSD TAW-1001D-100L   1-in-1-out analog two-wire 4-20mA isolation transmitter (short shell)
JSD TAW-2002D-100L   2-in-2-out analog two-wire 4-20mA isolation transmitter (short shell)
JSD TAW-1001-100L     1-in-1-out analog two-wire 4-20mA isolation transmitter
JSD TAW-2002-100L     2-in-2-out analog two-wire 4-20mA isolation transmitter
JSD TAW-3003-100L     3-in-3-out analog two-wire 4-20mA isolation transmitter
JSD TAW-4004-100L     4-in-4-out analog two-wire 4-20mA isolation transmitter

B, Two-wire loop power supply
JSD TAW-1001D-100L-F  1-in-1-out analog two-wire 4-20mA loop power isolation transmitter (short shell)
JSD TAW-2002D-100L-F  1-in-1-out analog two-wire 4-20mA loop power isolation transmitter (short shell)
JSD TAW-1001-100L-F   1-in-1-out analog two-wire 4-20mA loop power supply isolation transmitter
JSD TAW-2002-100L-F   2-in-2-out analog two-wire 4-20mA loop power supply isolation transmitter
JSD TAW-3003-100L-F   3-in-3-out analog two-wire 4-20mA loop power supply isolation transmitter
JSD TAW-4004-100L-F   4-in-4-out analog two-wire 4-20mA loop power supply isolation transmitter

C,Voltage input two-wire output loop power supply
JSD TAW-1001D-100L-V            1-in-1-out voltage input two-wire 4-20mA output loop power isolation transmitter
JSD TAW-2002D-100L-V            2-in-2-out voltage input two-wire 4-20mA output loop power isolation transmitter

2, Optical isolation passive series (two-wire 4-20mA Current loop Transmitters) 
JSD TAW-1001D-100L-P     1-in-1-out analog two-wire 4-20mA Current loop isolation transmitter (short shell)
JSD TAW-2002D-100L-P     2-in-2-out analog two-wire 4-20mA Current loop isolation transmitter (short shell)
JSD TAW-1001-100L-P       1-in-1-out analog two-wire 4-20mA Current loop isolation transmitter
JSD TAW-2002-100L-P       2-in-2-out analog two-wire 4-20mA Current loop isolation transmitter
JSD TAW-3003-100L-P       3-in-3-out analog two-wire 4-20mA Current loop isolation transmitter
JSD TAW-4004-100L-P       4-in-4-out analog two-wire 4-20mA Current loop isolation transmitter

Isolation Transmitter (Magnetic Active Series)
1, Regular:
DIN35 1*1 MI       1-in-1-out analog signal isolation transmitter (short shell)
JSD TAM-1001      1-in-1-out analog signal isolation transmitter 
JSD TAM-1002      1-in-2-out analog signal isolation transmitter 
JSD TAM-1003      1-in-3-out analog signal isolation transmitter
JSD TAM-1004      1-in-4-out analog signal isolation transmitter 
JSD TAM-2002      2-in-2-out analog signal isolation transmitter 
JSD TAM-3003      3-in-3-out analog signal isolation transmitter 
2,input 2-wire:
JSD TAM-1021D    1-in-1-out input 2-wire isolation transmitter (short shell)
JSD TAM-1021     1-in-1-out input 2-wire isolation transmitter
JSD TAM-1022      1-in-2-out input 2-wire isolation transmitter
JSD TAM-1023      1-in-3-out input 2-wire isolation transmitter
JSD TAM-1024      1-in-4-out input 2-wire isolation transmitter
JSD TAM-2022      2-in-2out input 2-wire isolation transmitter
JSD TAM-3023      3-in-3-out input 2-wire isolation transmitter
3,input 2-wire/3-wire: 
JSD TAM-2311D      1-in-1-out input 2-wire/3-wire isolation transmitter (short shell)
4, input 3-wire:
JSD TAM-1031    1-in-1-out input 3-wire isolation transmitter
JSD TAM-1032    1-in-2-out input 3-wire isolation transmitter
JSD TAM-1033    1-in-3-out input 3-wire isolation transmitter
JSD TAM-1034    1-in-4-out input 3-wire isolation transmitter 
JSD TAM-2032    2-in-2-out input 3-wire isolation transmitter

Isolation transmitter (Magnetic isolation AC power supply series)
1, Regular:
JSD TAM-1501   1-in-1-out analog signal isolation transmitter
JSD TAM-1502   1-in-2-out analog signal isolation transmitter
JSD TAM-1503   1-in-3-out analog signal isolation transmitter
JSD TAM-2502   2-in-2-out analog signal isolation transmitter
JSD TAM-3503   3-in-3-out analog signal isolation transmitter
2,Input 2-wire:
JSD TAM-1521   1-in-1-out input 2-wire isolation transmitter
JSD TAM-1522   1-in-2-out input 2-wire isolation transmitter
JSD TAM-1523   1-in-3-out input 2-wire isolation transmitter
JSD TAM-1524   1-in-4-out input 2-wire isolation transmitter
JSD TAM-2522   2-in-2-out input 2-wire isolation transmitter
JSD TAM-3523   3-in-3-out input 2-wire isolation transmitter
3, Input 3-wire:
JSD TAM-1531   1-in-1-out input 3-wire isolation transmitter 
JSD TAM-1532   1-in-2-out input 3-wire isolation transmitter
JSD TAM-1533   1-in-3-out input 3-wire isolation transmitter
JSD TAM-2532   2-in-2-out input 3-wire isolation transmitter

Isolation Transmitter (Optical Isolation Active Series)
1, Regular:
JSD TA-1001D   1-in-1-out analog signal isolation transmitter (short shell)
JSD TA-1001    1-in-1-out analog signal isolation transmitter
JSD TA-1002    1-in-2-out analog signal isolation transmitter
JSD TA-1003    1-in-3-out analog signal isolation transmitter
JSD TA-1004    1-in-4-out analog signal isolation transmitter
JSD TA-2002    2-in-2-out analog signal isolation transmitter
JSD TA-3003    3-in-3-out analog signal isolation transmitter
2, Input 2-wire: 
JSD TA-1021    1-in-1-out input 2-wire isolation transmitter
JSD TA-1022    1-in-2-out input 2-wire isolation transmitter
JSD TA-1023    1-in-3-out input 2-wire isolation transmitter
JSD TA-1024    1-in-4-out input 2-wire isolation transmitter
JSD TA-2022    2-in-2-out input 2-wire isolation transmitter
JSD TA-3023    3-in-3-out input 2-wire isolation transmitter
3,Input 3-wire:
JSD TA-1031    1-in-1-out input 3-wire isolation transmitter 
JSD TA-1032    1-in-2-out input 3-wire isolation transmitter
JSD TA-2032    2-in-2-out input 3-wire isolation transmitter
4, Input 2-wire/3-wire:
JSD TA-1231D    1-in-1-out input 2-wire/3-wire isolation transmitter (short shell) 

Isolation Transmitter (AC power supply active series)
1, Regular:
JSD TA-1501    1-in-1-out analog signal isolation transmitter
JSD TA-1502    1-in-2-out analog signal isolation transmitter
JSD TA-1503    1-in-3-out analog signal isolation transmitter
JSD TA-2502    2-in-2-out analog signal isolation transmitter
JSD TA-3503    3-in-3-out analog signal isolation transmitter
2, Input 2-wire:
JSD TA-1521    1-in-1-out input 2-wire isolation transmitter
JSD TA-1522    1-in-2-out input 2-wire isolation transmitter
JSD TA-1523    1-in-3-out input 2-wire isolation transmitter
JSD TA-2522    2-in-2-out input 2-wire isolation transmitter
JSD TA-3523    3-in-3-out input 2-wire isolation transmitter
3, Input 3-wire:
JSD TA-1531    1-in-1-out input 3-wire isolation transmitter
JSD TA-1532    1-in-2-out input 3-wire isolation transmitter
JSD TA-1533    1-in-3-out input 3-wire isolation transmitter
JSD TA-2522    2-in-2-out input 3-wire isolation transmitter

Frequency pulse signal converter (V/F,F/V SERIES):
JSD TAF-1001S  1-in-1-out ultra-thin V/F(I/F)frequency pulse signal converter
JSD TAF-1021S  1-in-1-out input 2-wire ultra-thin V/F(I/F)frequency pulse signal converter
JSD TFA-1001   1-in-1-out F/V frequency pulse signal converter (frequency pulse to analog)
JSD TFA-1002   1-in-2-out F/V frequency pulse signal converter (frequency pulse to analog)
JSD TFA-2002   2-in-2-out F/V frequency pulse signal converter (frequency pulse to analog)

Differential signal isolation transmitter (strain bridge, pressure, tension, gravity ):
JSD TAB-1001S  1-in-1-out differential signal isolation transmitter (tension, gravity signal)
JSD TAB-2002   2-in-2-out differential signal isolation transmitter (tension, gravity signal)

Analog mV Small Isolation Transmitter: 
JSD TAMS-1001D  1-in-1-out Analog mV Small Isolation Transmitter:

Isolated power transmitter: (small power, medium power, high power)
JSD TAP-1001    
1-in-1-out isolation power transmitter(used to drive solenoid valves, relays, solenoid proportional valves, etc.,small power series)
JSD TAP-1001M   
1-in-1-out isolation power transmitter(used to drive solenoid valves, relays, solenoid proportional valves, etc.,medium power series)
JSD TAP-1001H   

1-in-1-out isolation power transmitter (used to drive solenoid valves, relays, solenoid proportional valves, etc.,high power series)
High voltage(high current)signal isolation transmitter:(IN: 0-2000VDC,0-100ADC,etc.)
JSD TAH-1001   1-in-1-out high voltage (high current) signal isolation transmitter
JSD TAH-1002   1-in-2-out high voltage (high current) signal isolation transmitter

Thermal resistance signal isolation transmitter: (such as Pt10,Pt100,Pt1000,Cu100,etc.)
JSD TARZ-1001  1-in-1-out thermal resistance temperature signal isolation transmitter
JSD TARZ-1002  1-in-2-out thermal resistance temperature signal isolation transmitter
JSD TARZ-2002  2-in-2-out thermal resistance temperature signal isolation transmitter

Thermocouple temperature signal isolation transmitter: (such as B,E , K, S, T type,etc.)
JSD TTC-1001   1-in-1-out thermocouple signal isolation transmitter
JSD TTC-1002   1-in-2-out thermocouple signal isolation transmitter
JSD TTC-2002   2-in-2-out Thermocouple Signal Isolation Transmitter

Thermistor signal isolation transmitter: (such as NTC, etc.)
JSD TTR-1001D  1-in-1-out thermistor signal isolation transmitter

Resistance signal isolation transmitter: (resistance, electronic ruler, potentiometer, potentiometer, displacement)
JSD TAR-1001   1-in-1-out resistance signal isolation transmitter
JSD TAR-1002   1-in-2-out resistance signal isolation transmitter
JSD TAR-2002   2-in-2-out Resistance Signal Isolation Transmitter

AC signal isolation transmitter: (such as AC0-380V, 0-5AAC, 0-10AAC, etc.)
JSD TAE-1001D  1-in-1-out AC signal isolation transmitter (AC signal to DC signal)

Speed sensor signal isolation transmitter: 
JSD TAS-1001D  1-in-1-out speed sensor signal isolation transmitter

PWM pulse width signal isolation transmitter: (analog to PWM, PWM to analog)
JSD TAG-1001   1-in-1-out PWM pulse signal isolation transmitter (analog signal to PWM pulse width modulation)
JSD TGA-1001   1-in-1-out PWM pulse signal isolation transmitter (PWM pulse width modulation to analog signal)

High-speed signal isolation transmitter: (measure analog signal, fast frequency, short response time)
JSD TA-1001F  One input one output high-speed signal isolation transmitter
JSD TA-1002F  1-in-2-out high-speed signal isolation transmitter
JSD TA-2002F  2-in-2-out High Speed Signal Isolation Transmitter

2-in-1-out Automatic selection signal isolation transmitter:
JSD TA-1231C  2-in-1-out optional signal isolation transmitter
JSD TA-2001C  2-in-1-out Automatic selection signal isolation transmitter

Data acquisition module: (A/D, D/A, switch converter)
JSD AD11           one way A/D data acquisition module
JSD AD81           8-channel A/D data acquisition module
JSD DA02           dual D/A data acquisition module
JSD RM-4004     4-channel dry contact relay isolation module
JSD SD08            Eight-channel D/A switch data acquisition module
JSD SD16            16-channel D/A switch data acquisition module
JSD ADNF-8008   8-channel coded pulse counter, angular velocity displacement measurement data acquisition module
Remarks: special requirements, special parameters, special products can be professionally customized, welcome to call and negotiate
Package size: (more details please into our official website: )

RS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a ConverterRS232/RS485 Digital Signal to Analog 4-20mA Signal Isolation D/a Converter

Send your message to this supplier

*From:
*To: