• Thermocouple Temperature 4-20mA Signal Isolator
  • Thermocouple Temperature 4-20mA Signal Isolator
  • Thermocouple Temperature 4-20mA Signal Isolator
  • Thermocouple Temperature 4-20mA Signal Isolator
  • Thermocouple Temperature 4-20mA Signal Isolator
  • Thermocouple Temperature 4-20mA Signal Isolator

Thermocouple Temperature 4-20mA Signal Isolator

Type: Electromagnetic
Output Signal Type: Analog Output
Production Process: Jieshengda
Material: PA66
Accuracy Grade: 0.1G
Application: Automate
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Guangdong, China

Basic Info.

Model NO.
JSD TTC-1001
IP Rating
Three Prevention
Certification
CE
Customized
Non-Customized
Input
K, E, S, B, J, T, R, N, Wre3-Wre25 and Wre5-Wre26
Output
0-3.3V/0-5V/0-10V/1-5V/4-20mA/0-20mA/0-10mA etc
Power
18-32VDC
High Linearity
0.1% F.S
Mtbf
500,000 Hours
Transport Package
Bubble Bag+Waterproof Bag
Specification
118.9*110*12.7
Trademark
jieshengda
Origin
Shenzhen. China
Production Capacity
9999

Product Description

thermocouple signal isolator
1-in-1-out thermocouple signal isolation transmitter
MODEL:JSD TTC-1001

Feature:
Small size, low cost, standard DIN35mm rail installation
Three-terminal isolation (input, output, power supply and mutual isolation between channels)
High precision grade (0.1% F.S, 0.2% F.S) and

High linearity (0.1% F.S)
High isolation withstand voltage (3000VDC/60S)
low temperature drift (40PPM/ºC)
Reliable product performance (MTBF>500,000 hours)
power supply (5/12/15/24 VDC and other single power supply)
International standard thermocouple signal input: K, E, S, B, J, T, R, N, WRe3-WRe25 and WRe5-WRe26, etc.
International standard signal output: 0-3.3V/0-5V/0-10V/1-5V/4-20mA/0-20mA/0-10mA etc.
Application:
Temperature signal measurement and monitoring
Equipment operation monitoring
Measurement of sensor signal
Analog mV small signal amplification, isolation and conversion
Industrial field signal isolation and long-distance long-distance transmission without distortion
Analog signal ground wire interference suppression
Instrumentation and sensor signal transmission and reception
Small signal collection, measurement, amplification and distortion-free remote transmission of various temperature in industrial site
Building automation control

General Description:
The JSD TTC-1001 series of JSD Technology is a thermocouple signal isolation transmitter with one input and one output. This product is an isolation transmitter that uses a thermocouple sensor to measure temperature (the thermocouple sensor needs to be equipped by the user). Mainly used to measure the temperature around -270ºC~+2800ºC. The thermocouple isolation transmitter JSD TTC-1001 is a digital circuit structure with a cold junction compensation function, and adopts advanced technologies such as ambient temperature self-compensation and zero point automatic calibration. It is calibrated according to the thermocouple national standard graduation table before leaving the factory, so it can It is guaranteed that the accuracy is within the specified range for many years, without frequent calibration. The product has functions such as online fault self-diagnosis, and is an intelligent temperature transmitter product.

JSD TTC-1001 series of JSD TTC-1001 are completely isolated (three isolation) between input, output and working power supply. The product adopts SMD and wide creepage design, which can make the product withstand 3000VDC isolation withstand voltage. The equipment adopts DIN35 international standard guide rail installation method, which is small in size, high in accuracy, stable in performance, and cost-effective. It can be widely used in petroleum, chemical, electric power, instrumentation and industrial control industries.
For Single channel input dual-channel output thermocouple signal isolation transmitter Please choose: JSD TTC-1002 series; dual-channel thermocouple signal isolation transmitter Please choose JSD TTC-2002 series.
Selection List:
Product Selection Parameter List:
signal input code: Power supply: signal output code::
Input type Temperature range Power(VDC) current (mA) voltage(VDC)
1:B type 600-1800ºC W:18-32V 1:4-20mA 4:0-5V
2:E type       -270-1000ºC 1:24V 2:0-20mA 5:0-10V
3:J type -210-1200ºC 2:15V 3:0-10mA 6:1-5V
4:K type -200-1300ºC 3:12V   7:0-3.3V
5:N type -270-1300ºC 4:5V    
6:R type 0-1600ºC      
7:S type 0-1600ºC      
8:T type -270-400ºC      
9:WRe3-WRe25 0-2300ºC      
X:WRe5-WRe26 0-2300ºC      
U: User-defined U:User-defined U:User-defined
Note: special can be customized

Selection Example:
Example 1:input:K type,-200-1300ºC;output:4-20mA;power:24VDC;model:JSD TTC-1001-411

Example 2:input:T type, -270-400ºC;output:0-3VDC;power:24VDC;model:JSD TTC-1001-81U
Signs Item Test condition Min type Max Unit
Isolation
characteristics
Isolation voltage AC,50Hz,tested for 1 minute, humidity<70% leakage current < 1mA,)   3000   V(rms)
Insulation  resistance   ≥100    
Input
characteristics
Input (sensor  type) K,E,S,B,J,T,R,N,WRe3-WRe25 WRe5-WRe26  type
-270
 
+2800

ºC
Measurement accuracy 25ºC±2ºC, No cold junction compensation   ±0.1   % F.S
compensation accuracy: ±1ºC( 10 )  (preheating time 10 minutes)   ±1   ºC
Compensation range: -20ºC~+60ºC: -20ºC~+60ºC   -20~+60 ºC
Output characteristics Output signal voltage   0 10   VDC
current   0 20   mA
Response Time   0.5     S
Signal output ripple  Load 250Ω <5     mVrms
Power Supply
input characteristics
Power supply voltage   18 24 32 VDC
Power loss     0.7   W
range   - - - %
Other characteristics working temperature   -20   +60 ºC
storage temperature   -45   +85 ºC
size L*W*H 118.9*110*12.7 mm
Output status:
Follow mode: Under the circumstance that the user does not specifically specify, regardless of the fault state of the input signal (except for disconnection, the disconnection output is 0V/mA), the output will follow the input signal change within the full scale range, but the maximum output will not exceed the output 110% of the upper limit of the range (such as 0-20mA output, the minimum output can be 0mA, the maximum does not exceed 22mA).
Indicator light description:
PWR:Power indicator (green). When the meter is energized, it stays on.
ALM: Input signal status indicator, red. The indicator does not light up in normal working state;
The indicator flashes when the input signal fails;
When the input signal exceeds the range, the indicator will stay on.

Note :
When thermocouple is input, the compensation wire should be directly connected to the input terminal, and no wires of other materials should be connected in the middle, otherwise it will cause measurement errors
Pin function description:
Signal types Pin Function Pin Function
1 Signal Input- + 5 Signal Output + Standard DIN35
Rail
 mounting
2 Signal Input-+ 6 Signal Output -
3,7 No pin (NC) 9 Power supply In +
4,8 No pin (NC) 10 Power supply In -

Notes:
1,NC" pin must not be connected to any external circuit, otherwise it will damage the product itself;
2,Please read the user manual carefully before using. If any question please contact our technical support department.
3,Please do not use this product in hazardous area. The power supply of this product should be 24VDC power source. It is forbidden to use 220VAC power supply.
4,Calculating from the date of delivery, during normal use of the product, any quality problems are free repair or replacement by Company during 3 years warranty,
5,the product is strictly forbidden demolish without permission for not damage
6,All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
7,In this datasheet, all the test methods of indications are based on corporate standards.

Copyright:
Copyright © 2018 Shenzhen Jieshengda Technology Co., Ltd.
Without the prior written permission of the company, any content in this manual may not be copied, distributed, translated or transmitted in any form or method (electronic or mechanical), including photocopying, recording or storing in any information storage and retrieval system. This manual is subject to modification or update without notice.

Trademark
All other trademarks and copyrights belong to their respective owners.
Thermocouple Temperature 4-20mA Signal IsolatorThermocouple Temperature 4-20mA Signal IsolatorThermocouple Temperature 4-20mA Signal IsolatorThermocouple Temperature 4-20mA Signal IsolatorThermocouple Temperature 4-20mA Signal IsolatorThermocouple Temperature 4-20mA Signal Isolator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now