analog voltage and current signal to RS-232 or RS-485 data acquisition module
Quotation is not final sale price, please consult sales manager for details
Shenzhen JieShengdaTechnology Co., Ltd.
Are there any special products that can be customized and developed
Exhibition hall: https://jieshengdakj.en.made-in-china.com/
Features:
Analog signal acquisition, isolated RS-485/232 output
12-bit AD converter, testing accuracy>0.1%
Can be remotely reconfigured for modules accuracy by RS-485/232 Interface
Three-port isolation (input/output/power supply): 3000VDC /60s
Wide operating power supply: 8 ~ 32VDC
High reliability, easy programming and installation
International standard DIN35mm rail mounting for easy centralized wiring
Can Program setting module address, baud rate , etc.
Supports Modbus RTU
Low cost, small size modular design
Applications:
Analog signal testing/monitoring/control
RS-485 remote I / O, data acquisition
Intelligent building control, security engineering and other applications
RS-232/485 industrial automation control system
Industrial field signal isolation and long-term transmission
Monitoring equipment operation
sensor signal measurement
Industrial data acquisition and recording
medical, industrial product development
4-20mA/0-5V or 1-5V signal acquisition
General Description:
JSD AD11 series products realize the signal acquisition between sensor and host, to measure analog signals. JSD AD11series products can be applied to RS-232/485 bus industrial automation control system, 4-20mA / 0-5V signalmeasurement, monitoring and controlling, 0-75mV, 0-100mV and other small-signals measurement and signals isolationand long-term industrial transmission and so on. Products include power supply isolation, signal isolation, linearization,A/D conversion and RS-485 serial communication. Each serial interface can connect up to 255 pieces JSD AD11 Seriesmodules, communication using ASCII code or MODBUS RTU communication protocol, and its instruction setcompatible with the ADAM modules, baud rate can be set by the code, with other manufacturers control module hang inthe same RS-485 bus for easy programmingPicture 2: JSD AD11 module internal block diagram Analog signals to RS-485/RS-232 data acquisition A / D converter JSD AD11 seriesThe copyright and products interpretation own to Shenzhen Jie Sheng Technology Co., Ltd. products update without noticeShenzhen jieshengda Technology Co., Ltd.Coofficial
JSD AD11 series is based on SCM intelligent monitoring and control system, all of the users set configurationinformation such as Calibration value, address, baud rate, data format, checksum and status are stored in non-volatilememory EEPROM.
JSD AD11 series products according to industry standard design and manufacture .They are three-port isolation(input,output and power supply),and the isolation voltage between them is up to 3000 VDC, JSD AD11 series products havebetter Anti-interference ability, high reliability and wide operating Temperature Range (- 45ºC~+85ºC.)Function Description:JSD AD11 signal isolation acquisition module can be used to measure one channel voltage or current signal,
1. Analog signal input12-Bit acquisition accuracy, all products signal input range have been calibrated. In using, users also can programCalibrate easily. About the specific current or voltage input range, please see product selection.
2. Communication protocolCommunication Interface: one channel standard RS-485 communication interface, or one channel standard RS-232Communication interface, specify when ordering.Communication Protocols: supports two protocols, characters protocol of the command set defined and MODBUSRTU communication protocol. Can be programmed using the kind of communication protocol, can be achieved withPLC, RTU of many Brands or computer monitoring system for networking communication.Data Format: 10 Bits. 1 start bit,8 data bits,1 stop bit.Address: (0 to 255) and baud rate (1200,2400,4800,9600,19200,38400bps) can be set, the most long-distance aboutcommunication networks is up to 1200 meters, through the twisted-pair shielded cable.Communication interface of high anti-jamming design, ± 15KV ESD protection, communication response time is lessthan 100mS.
3. Anti-jammingAccording to need to set the checksum. Module internal has transient suppression diodes, can inhibit a variety of surgepulse, protection module, and internal digital filter can also be well suppressed from the grid frequency interference.
Product Selection:
Sample 1: Model: JSD AD11-I4-485 4-20mA input,RS485 interface output
Sample 2:Model :JSD AD11-V1-232 0-5V input,
RS-232 interface output General parameters: (typical @ +25 ºC, V s to 24VDC)
Input type: current/voltage input Accuracy: 0.1%
Temperature drift:±30ppm/ºC(±50ppm/ºC max)
Input Resistance: 50ohm(4-20mA/0-20mA/0- ± 20mA current input)
100ohm(0-10mA/0- ± 10mA current input)1Kohm(0-1mA/0- ± 1mA current input)>1Mohm(voltage input)
Bandwidth: -3 dB 10 Hz
Conversion rate: 10 SpsCommon
Mode Rejection (CMR): 120 dB (1kohm Source Imbalance @ 50/60 Hz)Normal Mode Rejection (NMR): 60 dB (1kohm Source Imbalance @ 50/60 Hz)
Input Protection: over-voltage protection, over-current protectionCommunication: RS-485 protocol or RS-232 , standard characters protocols and MODBUS RTUcommunication protocolBaud Rate (1200,2400,4800,9600,19200,38400 bps) can be selected via softwareAddress (0 to 255) can be selected via softwareCommunication Response Time: 100 ms maximum
Power Supply: +8~32VDC wide range power supply, internal anti-reverse and over-voltage protectioncircuit
Power Loss: less than 1W
Operating Temperature: -45~+80ºC
Operating Humidity: 10~90% (no condensation)
Storage Temperature: -45~+80 ºC
Storage Humidity: 10~95%(no condensation)
Isolation Voltage: input / output: 3KVDC/1 minute,
leakage current:1mAWhich output signal and power supply are common ground.
Shock Voltage: 3KVAC, 1.2/50us (peak)
Dimensions: 106.7 mm x 79 mm x 25mm
Product Dimensions:
Notes:
1,NC pin must not be connected to any external circuit, otherwise it will damage the product itself;
2,Please read the user manual carefully before using. If any question please contact our technical support department.
3,Please do not use this product in hazardous area. The power supply of this product should be DC power source. It is forbidden to use 220VAC power supply.
4,Calculating from the date of delivery, during normal use of the product, any quality problems are free repair or replacement by Company during 3 years warranty
5,the product is strictly forbidden demolish without permission for not damage
6,All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
7,In this datasheet, all the test methods of indications are based on corporate standards.
Jieshengda Technology (JSD Technology) Introduction:
Shenzhen Jieshengda Technology Co., Ltd. is a high-tech enterprise that integrates research, development, production, and trade. The company specializes in AC-DC power modules, DC-DC power modules, micro power DC-DC module power supplies, medium power modules, high-voltage module power supplies, two wire 4-20mA isolation amplifier modules, isolation amplifiers, mV small signal isolation amplifiers, differential (pressure, tension, gravity) strain bridge signal isolation amplifiers Isolation transmitter, two wire 4-20mA isolation transmitter, RTD Pt100 thermal resistance signal isolation transmitter, thermocouple temperature isolation transmitter, AC voltage and current (electricity) signal isolation transmitter, NTC thermal resistance signal isolation transmitter, absolute value isolation transmitter, frequency pulse signal converter (V/F frequency pulse converter, F/V frequency pulse converter), differential (pressure, tension, gravity) strain bridge signal isolation transmitter Speed sensor signal isolation transmitter, high voltage and high current signal isolation transmitter, isolation power drive transmitter (current and voltage signal amplification), resistance (potentiometer/potentiometer/electronic ruler) displacement signal isolation transmitter, milliohm (mR) resistance signal isolation transmitter, PWM pulse width signal isolation transmitter (analog to PWM pulse signal, PWM pulse width signal to analog signal) A high-tech enterprise that automatically selects isolation transmitters and programmable analog isolation transmitters (which can replace foreign multi signal inputs), and develops, produces, and sells isolation transmitter products such as relays, thermal resistance signal relays, thermocouple relays, RS-485 relays, non isolation amplifiers, and data acquisition modules (A/D data acquisition, D/A data acquisition). The entire series of products have passed CE and RoHS certifications, and the company has passed ISO9001 quality management system certification. Our self-developed products comply with international standards and are compatible with the vast majority of well-known brands both domestically and internationally. Our product range covers thousands of different types, making us one of the manufacturers of analog and digital signal hybrid integrated circuits in industrial automation and industrial control automation.
The company has passed ISO9001 quality management system certification. The products developed by ourselves are in line with international standards and are compatible with most famous brands at home and abroad. The product types cover more than thousands. It is the simulation of industrial automation and industrial automation. One of the manufacturers of hybrid ICs for signal and digital signals.
Since its inception, Jieshengda Technology has focused on high-end technology application research and development of sensor, isolator transmitter analog signal acquisition, isolation amplification and transformation, and current state-developed rail transit, national grid transformation, wind energy solar power generation, Emerging industries such as electric vehicles are in great demand for matching key electronic components. Through the unremitting efforts of all Jieshengda people, the products have been successfully applied in aerospace control, atomic energy research and development institutions, power, communication, instrumentation, industrial measurement systems, medical equipment, industrial control intelligence, automotive intelligence, intelligent building control, automotive electronics. , security, environmental protection, food, heating and cooling air conditioning systems, water treatment, petrochemical, coal mining, metallurgy, ships and many other fields have been widely used. Under the premise of ensuring quality and reasonable cost performance, we provide products with different functions to customers in different fields. When customers need special products, they can customize related products for customers, provide satisfactory and reasonable solutions for customers, and get favorable comments from customers.
The company has established a "people-oriented, customer first, forge ahead, and common development" business purposes, with "integrity, pragmatism, dedication, innovation" as the management philosophy, the company relies on science and technology for development, and constantly provide users with satisfactory high-tech products, It is the constant pursuit of all Jieshengda people.
Today, Jieshengda people pursue the policy of "aggressive and realistic, rigorous and united", and constantly develop and innovate. "Technology as the core, quality as the life, and action to prove" will provide you with cost-effective products and provide you with The most professional one-stop after-sales service.
Advantage:
The company has R&D talents specialized in the industry for more than ten years, and cooperates with many universities and research institutes. The production cycle is short, the delivery time is fast, the price is more reasonable, and the modular (IC package) design has high integration. The products have passed CE certification and RoHS certification, the company has passed ISO9001 quality management system certification, and can also customize special products for customers.
Products List
AC-DC converter series:
JSD Ax-DxS(D)220 (International standard DIP packaging)
JSD DAx-xxS(D)220 (International standard DIN35 rail mounting)
DC-DC converter series:
Rated voltage input series:
AxxxxS(D)-xW Rated voltage Input isolated unregulated positive & negative voltage output series
BxxxxS(D)-xW Rated voltage Input isolated unregulated positive voltage output
BxxxxM-xW Rated voltage Input isolated unregulated positive voltage output
BxxxxLS(D)-xW Rated voltage Input isolated unregulated positive voltage output
DxxxxS(D)-xW Rated voltage input isolated unregulated positive voltage dual output
ExxxxS(D)-xW Rated voltage Input isolated unregulated positive& negative voltage output
FxxxxS(D)-xW Rated voltage Input isolated unregulated positive voltage output
GxxxxS-xW Rated voltage Input isolated unregulated positive & negative voltage output
HxxxxS-xW Rated voltage Input isolated unregulated positive voltage output
BxxxxULP Rated voltage input unregulated isolated ultra-low power positive voltage output series
High voltage module power supply series: (input range: 2:1)
HVMDx-xxSxx Wide-range Voltage Input Non-Isolated Regulated High Voltage Single Output
HVMLDx-xxSxx Wide- range Voltage Input Non-Isolated Regulated High Voltage Single Output
High voltage module power supply series: (input range: 2:1)
HVMDx-xxSxx Wide- range Voltage Input Non-Isolated Regulated High Voltage Single Output
HVMLDx-xxSxx Wide- range Voltage Input Non-Isolated Regulated High Voltage Single Output
Regulated Voltage Output:(input range: ±5%)
IAxxxxS-xW Rated voltage Input isolated regulated positive& negative voltage output
IBxxxxLS(D)-xW Rated voltage Input isolated regulated positive voltage output
IExxxxS-xW Rated voltage Input isolated regulated positive& negative voltage output
IFxxxxS-xW Rated voltage Input isolated regulated positive voltage output
Regulated Voltage Output Series:( input range: ±10%)
VAxxxxS-xW Rated voltage Input isolated regulated positive& negative voltage output
VBxxxxLS(D)-xW Rated voltage Input isolated regulated positive voltage output
VExxxxS-xW Rated voltage Input isolated regulated positive& negative voltage output
VFxxxxS-xW Rated voltage Input isolated regulated positive voltage output
Regulated Voltage Output Series:( input range: 2:1)
WRAxxxxD-xW 2:1 Wide- range Voltage Input Isolated Regulated positive Voltage Output
WRBxxxxD-xW 2:1 Wide- range Voltage Input Isolated Regulated positive Voltage Output
WRAxxxxLD-xW 2:1 Wide- range Voltage Input Isolated Regulated positive& negative Voltage Output
WRBxxxxLD-xW 2:1 Wide- range Voltage Input Isolated Regulated positive Voltage Output
Regulated Voltage Output Series:( input range: 4:1)
URAxxxxD-xW 4:1 Wide- range Voltage Input Isolated Regulated positive& negative Voltage Output
URBxxxxD-xW 4:1 Wide- range Voltage Input Isolated Regulated positive Voltage Output
Isolation Amplifier
JSD TAW-100L Two-wire analog passive 4-20mA isolation amplifier
JSD TAW-100L-F Two-wire analog passive 4-20mA input loop isolation distributor
JSD TAW-100L-P Two-wire analog passive 4-20mA output loop power supply isolation amplifier
JSD OI-V(I)x-Px-V(I)Ox Analog Signal Isolation Amplifier (Optical Isolation Series)
JSD TA-101L Analog Signal Isolation Amplifier (New)
JSD MI-V(I)x-Px-V(I)Ox Positive&negative signal isolation amplifier (magnetic isolation series)
JSD TAM-101L Analog Signal Isolation Amplifier (New)
JSD OI-MSx-Px-V(I)Ox Analog mV Signal Isolation Amplifier (Optical Isolation Series)
JSD TAMS-101L Analog mV Signal Isolation Amplifier (SIP12,New)
JSD OI-Bx-Px-V(I)Ox Differential signal isolation amplifier(strain bridge, pressure, tension, gravity) s
JSD NI-V(I)x-Px-V(I)Ox Analog Signal Non-Isolated Amplifier
JSD TAN-101L Analog Signal Non-Isolated Amplifier (New)
Isolation Transmitter (magnetic& Optical Isolation Passive Series)
1, Magnetic isolation
Passive series (conventional, loop power supply, output loop power supply, voltage input and output two-wire loop power supply)
A, Regular Two-wire
JSD TAW-1001D-100L 1-in-1-out analog two-wire 4-20mA isolation transmitter (short shell)
JSD TAW-2002D-100L 2-in-2-out analog two-wire 4-20mA isolation transmitter (short shell)
JSD TAW-1001-100L 1-in-1-out analog two-wire 4-20mA isolation transmitter
JSD TAW-2002-100L 2-in-2-out analog two-wire 4-20mA isolation transmitter
JSD TAW-3003-100L 3-in-3-out analog two-wire 4-20mA isolation transmitter
JSD TAW-4004-100L 4-in-4-out analog two-wire 4-20mA isolation transmitter
B, Two-wire loop power supply
JSD TAW-1001D-100L-F 1-in-1-out analog two-wire 4-20mA loop power isolation transmitter (short shell)
JSD TAW-2002D-100L-F 1-in-1-out analog two-wire 4-20mA loop power isolation transmitter (short shell)
JSD TAW-1001-100L-F 1-in-1-out analog two-wire 4-20mA loop power supply isolation transmitter
JSD TAW-2002-100L-F 2-in-2-out analog two-wire 4-20mA loop power supply isolation transmitter
JSD TAW-3003-100L-F 3-in-3-out analog two-wire 4-20mA loop power supply isolation transmitter
JSD TAW-4004-100L-F 4-in-4-out analog two-wire 4-20mA loop power supply isolation transmitter
C,Voltage input two-wire output loop power supply
JSD TAW-1001D-100L-V 1-in-1-out voltage input two-wire 4-20mA output loop power isolation transmitter
JSD TAW-2002D-100L-V 2-in-2-out voltage input two-wire 4-20mA output loop power isolation transmitter
2, Optical isolation passive series (two-wire 4-20mA Current loop Transmitters)
JSD TAW-1001D-100L-P 1-in-1-out analog two-wire 4-20mA Current loop isolation transmitter (short shell)
JSD TAW-2002D-100L-P 2-in-2-out analog two-wire 4-20mA Current loop isolation transmitter (short shell)
JSD TAW-1001-100L-P 1-in-1-out analog two-wire 4-20mA Current loop isolation transmitter
JSD TAW-2002-100L-P 2-in-2-out analog two-wire 4-20mA Current loop isolation transmitter
JSD TAW-3003-100L-P 3-in-3-out analog two-wire 4-20mA Current loop isolation transmitter
JSD TAW-4004-100L-P 4-in-4-out analog two-wire 4-20mA Current loop isolation transmitter
Isolation Transmitter (Magnetic Active Series)
1, Regular:
DIN35 1*1 MI 1-in-1-out analog signal isolation transmitter (short shell)
JSD TAM-1001 1-in-1-out analog signal isolation transmitter
JSD TAM-1002 1-in-2-out analog signal isolation transmitter
JSD TAM-1003 1-in-3-out analog signal isolation transmitter
JSD TAM-1004 1-in-4-out analog signal isolation transmitter
JSD TAM-2002 2-in-2-out analog signal isolation transmitter
JSD TAM-3003 3-in-3-out analog signal isolation transmitter
2,input 2-wire:
JSD TAM-1021D 1-in-1-out input 2-wire isolation transmitter (short shell)
JSD TAM-1021 1-in-1-out input 2-wire isolation transmitter
JSD TAM-1022 1-in-2-out input 2-wire isolation transmitter
JSD TAM-1023 1-in-3-out input 2-wire isolation transmitter
JSD TAM-1024 1-in-4-out input 2-wire isolation transmitter
JSD TAM-2022 2-in-2out input 2-wire isolation transmitter
JSD TAM-3023 3-in-3-out input 2-wire isolation transmitter
3,input 2-wire/3-wire:
JSD TAM-2311D 1-in-1-out input 2-wire/3-wire isolation transmitter (short shell)
4, input 3-wire:
JSD TAM-1031 1-in-1-out input 3-wire isolation transmitter
JSD TAM-1032 1-in-2-out input 3-wire isolation transmitter
JSD TAM-1033 1-in-3-out input 3-wire isolation transmitter
JSD TAM-1034 1-in-4-out input 3-wire isolation transmitter
JSD TAM-2032 2-in-2-out input 3-wire isolation transmitter
Isolation transmitter (Magnetic isolation AC power supply series)
1, Regular:
JSD TAM-1501 1-in-1-out analog signal isolation transmitter
JSD TAM-1502 1-in-2-out analog signal isolation transmitter
JSD TAM-1503 1-in-3-out analog signal isolation transmitter
JSD TAM-2502 2-in-2-out analog signal isolation transmitter
JSD TAM-3503 3-in-3-out analog signal isolation transmitter
2,Input 2-wire:
JSD TAM-1521 1-in-1-out input 2-wire isolation transmitter
JSD TAM-1522 1-in-2-out input 2-wire isolation transmitter
JSD TAM-1523 1-in-3-out input 2-wire isolation transmitter
JSD TAM-1524 1-in-4-out input 2-wire isolation transmitter
JSD TAM-2522 2-in-2-out input 2-wire isolation transmitter
JSD TAM-3523 3-in-3-out input 2-wire isolation transmitter
3, Input 3-wire:
JSD TAM-1531 1-in-1-out input 3-wire isolation transmitter
JSD TAM-1532 1-in-2-out input 3-wire isolation transmitter
JSD TAM-1533 1-in-3-out input 3-wire isolation transmitter
JSD TAM-2532 2-in-2-out input 3-wire isolation transmitter
Isolation Transmitter (Optical Isolation Active Series)
1, Regular:
JSD TA-1001D 1-in-1-out analog signal isolation transmitter (short shell)
JSD TA-1001 1-in-1-out analog signal isolation transmitter
JSD TA-1002 1-in-2-out analog signal isolation transmitter
JSD TA-1003 1-in-3-out analog signal isolation transmitter
JSD TA-1004 1-in-4-out analog signal isolation transmitter
JSD TA-2002 2-in-2-out analog signal isolation transmitter
JSD TA-3003 3-in-3-out analog signal isolation transmitter
2, Input 2-wire:
JSD TA-1021 1-in-1-out input 2-wire isolation transmitter
JSD TA-1022 1-in-2-out input 2-wire isolation transmitter
JSD TA-1023 1-in-3-out input 2-wire isolation transmitter
JSD TA-1024 1-in-4-out input 2-wire isolation transmitter
JSD TA-2022 2-in-2-out input 2-wire isolation transmitter
JSD TA-3023 3-in-3-out input 2-wire isolation transmitter
3,Input 3-wire:
JSD TA-1031 1-in-1-out input 3-wire isolation transmitter
JSD TA-1032 1-in-2-out input 3-wire isolation transmitter
JSD TA-2032 2-in-2-out input 3-wire isolation transmitter
4, Input 2-wire/3-wire:
JSD TA-1231D 1-in-1-out input 2-wire/3-wire isolation transmitter (short shell)
Isolation Transmitter (AC power supply active series)
1, Regular:
JSD TA-1501 1-in-1-out analog signal isolation transmitter
JSD TA-1502 1-in-2-out analog signal isolation transmitter
JSD TA-1503 1-in-3-out analog signal isolation transmitter
JSD TA-2502 2-in-2-out analog signal isolation transmitter
JSD TA-3503 3-in-3-out analog signal isolation transmitter
2, Input 2-wire:
JSD TA-1521 1-in-1-out input 2-wire isolation transmitter
JSD TA-1522 1-in-2-out input 2-wire isolation transmitter
JSD TA-1523 1-in-3-out input 2-wire isolation transmitter
JSD TA-2522 2-in-2-out input 2-wire isolation transmitter
JSD TA-3523 3-in-3-out input 2-wire isolation transmitter
3, Input 3-wire:
JSD TA-1531 1-in-1-out input 3-wire isolation transmitter
JSD TA-1532 1-in-2-out input 3-wire isolation transmitter
JSD TA-1533 1-in-3-out input 3-wire isolation transmitter
JSD TA-2522 2-in-2-out input 3-wire isolation transmitter
Frequency pulse signal converter (V/F,F/V SERIES):
JSD TAF-1001S 1-in-1-out ultra-thin V/F(I/F)frequency pulse signal converter
JSD TAF-1021S 1-in-1-out input 2-wire ultra-thin V/F(I/F)frequency pulse signal converter
JSD TFA-1001 1-in-1-out F/V frequency pulse signal converter (frequency pulse to analog)
JSD TFA-1002 1-in-2-out F/V frequency pulse signal converter (frequency pulse to analog)
JSD TFA-2002 2-in-2-out F/V frequency pulse signal converter (frequency pulse to analog)
Differential signal isolation transmitter (strain bridge, pressure, tension, gravity ):
JSD TAB-1001S 1-in-1-out differential signal isolation transmitter (tension, gravity signal)
JSD TAB-2002 2-in-2-out differential signal isolation transmitter (tension, gravity signal)
Analog mV Small Isolation Transmitter:
JSD TAMS-1001D 1-in-1-out Analog mV Small Isolation Transmitter:
Isolated power transmitter: (small power, medium power, high power)
JSD TAP-1001
1-in-1-out isolation power transmitter(used to drive solenoid valves, relays, solenoid proportional valves, etc.,small power series)
JSD TAP-1001M
1-in-1-out isolation power transmitter(used to drive solenoid valves, relays, solenoid proportional valves, etc.,medium power series)
JSD TAP-1001H
1-in-1-out isolation power transmitter (used to drive solenoid valves, relays, solenoid proportional valves, etc.,high power series)
High voltage(high current)signal isolation transmitter:(IN: 0-2000VDC,0-100ADC,etc.)
JSD TAH-1001 1-in-1-out high voltage (high current) signal isolation transmitter
JSD TAH-1002 1-in-2-out high voltage (high current) signal isolation transmitter
Thermal resistance signal isolation transmitter: (such as Pt10,Pt100,Pt1000,Cu100,etc.)
JSD TARZ-1001 1-in-1-out thermal resistance temperature signal isolation transmitter
JSD TARZ-1002 1-in-2-out thermal resistance temperature signal isolation transmitter
JSD TARZ-2002 2-in-2-out thermal resistance temperature signal isolation transmitter
Thermocouple temperature signal isolation transmitter: (such as B,E , K, S, T type,etc.)
JSD TTC-1001 1-in-1-out thermocouple signal isolation transmitter
JSD TTC-1002 1-in-2-out thermocouple signal isolation transmitter
JSD TTC-2002 2-in-2-out Thermocouple Signal Isolation Transmitter
Thermistor signal isolation transmitter: (such as NTC, etc.)
JSD TTR-1001D 1-in-1-out thermistor signal isolation transmitter
Resistance signal isolation transmitter: (resistance, electronic ruler, potentiometer, potentiometer, displacement)
JSD TAR-1001 1-in-1-out resistance signal isolation transmitter
JSD TAR-1002 1-in-2-out resistance signal isolation transmitter
JSD TAR-2002 2-in-2-out Resistance Signal Isolation Transmitter
AC signal isolation transmitter: (such as AC0-380V, 0-5AAC, 0-10AAC, etc.)
JSD TAE-1001D 1-in-1-out AC signal isolation transmitter (AC signal to DC signal)
Speed sensor signal isolation transmitter:
JSD TAS-1001D 1-in-1-out speed sensor signal isolation transmitter
PWM pulse width signal isolation transmitter: (analog to PWM, PWM to analog)
JSD TAG-1001 1-in-1-out PWM pulse signal isolation transmitter (analog signal to PWM pulse width modulation)
JSD TGA-1001 1-in-1-out PWM pulse signal isolation transmitter (PWM pulse width modulation to analog signal)
High-speed signal isolation transmitter: (measure analog signal, fast frequency, short response time)
JSD TA-1001F One input one output high-speed signal isolation transmitter
JSD TA-1002F 1-in-2-out high-speed signal isolation transmitter
JSD TA-2002F 2-in-2-out High Speed Signal Isolation Transmitter
2-in-1-out Automatic selection signal isolation transmitter:
JSD TA-1231C 2-in-1-out optional signal isolation transmitter
JSD TA-2001C 2-in-1-out Automatic selection signal isolation transmitter
Data acquisition module: (A/D, D/A, switch converter)
JSD AD11 one way A/D data acquisition module
JSD AD81 8-channel A/D data acquisition module
JSD DA02 dual D/A data acquisition module
JSD RM-4004 4-channel dry contact relay isolation module
JSD SD08 Eight-channel D/A switch data acquisition module
JSD SD16 16-channel D/A switch data acquisition module
JSD ADNF-8008 8-channel coded pulse counter, angular velocity displacement measurement data acquisition module
Remarks: special requirements, special parameters, special products can be professionally customized, welcome to call and negotiate
Package size: (more details please into our official website: )