• Analog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier
  • Analog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier
  • Analog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier
  • Analog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier
  • Analog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier
  • Analog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier

Analog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier

Kind: New-Type Transmitter
Type: DC Transmitter
Phase: Single
Wire-Assembly Type: Four-wire Transmitter
Accuracy Grade: 0.1G
Certification: CE
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Guangdong, China

Basic Info.

Model NO.
JSD AD11
Customized
Non-Customized
Input
0-5V/0-10V/1-5V/0-10mA/0-20mA /4-20mA/2-10V/0-3.3V
Output
RS-485/RS-232
Power
5V/12V/15V/24V/9-36VDC
High Accuracy
(0.1% F.S, 0.2% F.S)
High Isolation Voltage
(3000VDC/60s)
Operation Temperature
-45-+85
Transport Package
Bubble Bag+Waterproof Bag
Specification
107*79 * 25m
Trademark
jieshengda
Origin
Shenzhen
Production Capacity
99999

Product Description

 Analog signal 4-20mA to RS485/RS232 Converter Isolation Amplifier
Analog signal to RS485 or RS232 Converter, D/A Converter JSD AD11
https://jieshengdakj.en.made-in-china.com/product-list-1.html
Features:
Analog signal acquisition, isolated RS-485/232 output
12-bit AD converter, testing accuracy>0.1%
Can be remotely reconfigured for modules accuracy by RS-485/232 Interface
Three-port isolation (input/output/power supply): 3000VDC /60s
Wide operating power supply: 8 ~ 32VDC
High reliability, easy programming and installation
International standard DIN35mm rail mounting for easy centralized wiring
Can Program setting module address, baud rate , etc.
Supports Modbus RTU
Low cost, small size modular design 
Applications:
Analog signal testing/monitoring/control
RS-485 remote I / O, data acquisition
Intelligent building control, security engineering and other applications
RS-232/485 industrial automation control system
Industrial field signal isolation and long-term transmission
Monitoring equipment operation
sensor signal measurement
Industrial data acquisition and recording
medical, industrial product development
4-20mA/0-5V or 1-5V signal acquisition
General Description:
JSD AD11 series products realize the signal acquisition between sensor and host, to measure analog signals. JSD AD11series products can be applied to RS-232/485 bus industrial automation control system, 4-20mA / 0-5V signalmeasurement, monitoring and controlling, 0-75mV, 0-100mV and other small-signals measurement and signals isolationand long-term industrial transmission and so on. Products include power supply isolation, signal isolation, linearization,A/D conversion and RS-485 serial communication. Each serial interface can connect up to 255 pieces JSD AD11 Seriesmodules, communication using ASCII code or MODBUS RTU communication protocol, and its instruction setcompatible with the ADAM modules, baud rate can be set by the code, with other manufacturers control module hang inthe same RS-485 bus for easy programmingPicture 2: JSD AD11 module internal block diagram Analog signals to RS-485/RS-232 data acquisition A / D converter JSD AD11 seriesThe copyright and products interpretation own to Shenzhen Jie Sheng Technology Co., Ltd. products update without noticeShenzhen jieshengda Technology Co., Ltd.Coofficial  
JSD AD11 series is based on SCM intelligent monitoring and control system, all of the users set configurationinformation such as Calibration value, address, baud rate, data format, checksum and status are stored in non-volatilememory EEPROM.
JSD AD11 series products according to industry standard design and manufacture .They are three-port isolation(input,output and power supply),and the isolation voltage between them is up to 3000 VDC, JSD AD11 series products havebetter Anti-interference ability, high reliability and wide operating Temperature Range (- 45ºC~+85ºC.)Function Description:JSD AD11 signal isolation acquisition module can be used to measure one channel voltage or current signal,
1. Analog signal input12-Bit acquisition accuracy, all products signal input range have been calibrated. In using, users also can programCalibrate easily. About the specific current or voltage input range, please see product selection.
2. Communication protocolCommunication Interface: one channel standard RS-485 communication interface, or one channel standard RS-232Communication interface, specify when ordering.Communication Protocols: supports two protocols, characters protocol of the command set defined and MODBUSRTU communication protocol. Can be programmed using the kind of communication protocol, can be achieved withPLC, RTU of many Brands or computer monitoring system for networking communication.Data Format: 10 Bits. 1 start bit,8 data bits,1 stop bit.Address: (0 to 255) and baud rate (1200,2400,4800,9600,19200,38400bps) can be set, the most long-distance aboutcommunication networks is up to 1200 meters, through the twisted-pair shielded cable.Communication interface of high anti-jamming design, ± 15KV ESD protection, communication response time is lessthan 100mS.
3. Anti-jammingAccording to need to set the checksum. Module internal has transient suppression diodes, can inhibit a variety of surgepulse, protection module, and internal digital filter can also be well suppressed from the grid frequency interference. 
Product Selection:
Sample 1: Model: JSD AD11-I4-485 4-20mA input,RS485 interface output
Sample 2:Model :JSD AD11-V1-232 0-5V input,
RS-232 interface output General parameters: (typical @ +25 ºC, V s to 24VDC)
Input type: current/voltage input Accuracy: 0.1%
Temperature drift:±30ppm/ºC(±50ppm/ºC max)
Input Resistance: 50ohm(4-20mA/0-20mA/0- ± 20mA current input)
100ohm(0-10mA/0- ± 10mA current input)1Kohm(0-1mA/0- ± 1mA current input)>1Mohm(voltage input)
Bandwidth: -3 dB 10 Hz
Conversion rate: 10 SpsCommon
Mode Rejection (CMR): 120 dB (1kohm Source Imbalance @ 50/60 Hz)Normal Mode Rejection (NMR): 60 dB (1kohm Source Imbalance @ 50/60 Hz)
Input Protection: over-voltage protection, over-current protectionCommunication: RS-485 protocol or RS-232 , standard characters protocols and MODBUS RTUcommunication protocolBaud Rate (1200,2400,4800,9600,19200,38400 bps) can be selected via softwareAddress (0 to 255) can be selected via softwareCommunication Response Time: 100 ms maximum
Power Supply: +8~32VDC wide range power supply, internal anti-reverse and over-voltage protectioncircuit
Power Loss: less than 1W
Operating Temperature: -45~+80ºC
Operating Humidity: 10~90% (no condensation)
Storage Temperature: -45~+80 ºC
Storage Humidity: 10~95%(no condensation)
Isolation Voltage: input / output: 3KVDC/1 minute,
leakage current:1mAWhich output signal and power supply are common ground.
Shock Voltage: 3KVAC, 1.2/50us (peak)
Dimensions: 106.7 mm x 79 mm x 25mm
Product Dimensions:
Analog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier
Notes
:

1,NC pin must not be connected to any external circuit, otherwise it will damage the product itself;
2,Please read the user manual carefully before using. If any question please contact our technical support department.
3,Please do not use this product in hazardous area. The power supply of this product should be DC power source. It is forbidden to use 220VAC power supply.
4,Calculating from the date of delivery, during normal use of the product, any quality problems are free repair or replacement by Company during 3 years warranty
5,the product is strictly forbidden demolish without permission for not damage 
6,All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
7,In this datasheet, all the test methods of indications are based on corporate standards.
Analog Signal 4-20mA to RS485/RS232 Converter Isolation AmplifierAnalog Signal 4-20mA to RS485/RS232 Converter Isolation AmplifierAnalog Signal 4-20mA to RS485/RS232 Converter Isolation AmplifierAnalog Signal 4-20mA to RS485/RS232 Converter Isolation AmplifierAnalog Signal 4-20mA to RS485/RS232 Converter Isolation Amplifier

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.