Jieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation Amplifier

Product Details
Customization: Available
Task: Adjust
Structure: Closed-Loop
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Jieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation Amplifier
  • Jieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation Amplifier
  • Jieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation Amplifier
  • Jieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation Amplifier
  • Jieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation Amplifier
  • Jieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation Amplifier
Find Similar Products

Basic Info.

Model NO.
JSD TAB-1001S-2115
Signal
Signal Isolation Amplifier
Function
Automatic Control
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Non-Customized
Material
PA66
Input
1mv/V;2mv/V;0-10mv/0-20mv/0-500mv
Output
4-20mA/0-20mA/0-10V/0-5V/0-3.3V
Power
5V/12V/15V/24V/8-40VDC
Isolation Voltage
3000VDC
High Accuracy
0.1% F.S,0.2% F.S
Transport Package
Bubble Bag+Waterproof Bag
Specification
115*100*12.5mm
Trademark
jieshengda
Origin
Shenzhen. China
Production Capacity
9999

Product Description

JSD TAB-1001S series pressure strain bridge isolated transmitter is a kind of differential signal (pressure, tension, gravity sensor equipment signals) isolation amplification, converted into proportional output DC signal isolation product, the pressure strain bridge isolated transmitter can provide a set of isolated high efficiency and high precision reference voltage source for pressure sensors. The small signal output of the synchronous sensor of the reference voltage source is provided for amplification, isolation and remote transmission. The product can provide a group of high-precision voltage source for pressure, tension, gravity sensor, the group of reference voltage source voltage is optional (5VDC\10VDC\12VDC), the differential signal isolation transmitter internal SMD process design and multi-channel efficient isolation power supply, so that the signal input (excitation voltage), working power supply, signal output between each other. Isolation voltage up to 3000VDC above, the differential transmitter adopts photoelectric isolation technology, compared with the magnetic electric isolation converter stronger anti-EMC electromagnetic interference and high-frequency signal interference characteristics, products are widely used in power, instrumentation, medical equipment, weighing instruments, industrial automation and other industrial fields. The product is the international standard DIN 35mm guide card slot fixed installation mode, user wiring can be used.JSD TAB-1001S series pressure strain bridge isolated transmitter is a kind of differential signal (pressure, tension, gravity sensor equipment signals) isolation amplification, converted into proportional output DC signal isolation product, the pressure strain bridge isolated transmitter can provide a set of isolated high efficiency and high precision reference voltage source for pressure sensors. The small signal output of the synchronous sensor of the reference voltage source is provided for amplification, isolation and remote transmission. The product can provide a group of high-precision voltage source for pressure, tension, gravity sensor, the group of reference voltage source voltage is optional (5VDC\10VDC\12VDC), the differential signal isolation transmitter internal SMD process design and multi-channel efficient isolation power supply, so that the signal input (excitation voltage), working power supply, signal output between each other. Isolation voltage up to 3000VDC above, the differential transmitter adopts photoelectric isolation technology, compared with the magnetic electric isolation converter stronger anti-EMC electromagnetic interference and high-frequency signal interference characteristics, products are widely used in power, instrumentation, medical equipment, weighing instruments, industrial automation and other industrial fields. The product is the international standard DIN 35mm guide card slot fixed installation mode, user wiring can be usedJSD TAB-1001S series pressure strain bridge isolated transmitter is a kind of differential signal (pressure, tension, gravity sensor equipment signals) isolation amplification, converted into proportional output DC signal isolation product, the pressure strain bridge isolated transmitter can provide a set of isolated high efficiency and high precision reference voltage source for pressure sensors. The small signal output of the synchronous sensor of the reference voltage source is provided for amplification, isolation and remote transmission. The product can provide a group of high-precision voltage source for pressure, tension, gravity sensor, the group of reference voltage source voltage is optional (5VDC\10VDC\12VDC), the differential signal isolation transmitter internal SMD process design and multi-channel efficient isolation power supply, so that the signal input (excitation voltage), working power supply, signal output between each other. Isolation voltage up to 3000VDC above, the differential transmitter adopts photoelectric isolation technology, compared with the magnetic electric isolation converter stronger anti-EMC electromagnetic interference and high-frequency signal interference characteristics, products are widely used in power, instrumentation, medical equipment, weighing instruments, industrial automation and other industrial fields. The product is the international standard DIN 35mm guide card slot fixed installation mode, user wiring can be used2mV/V to 0-10V Pressure strain bridge Isolation amplifier
JSD TAB-1001S series pressure strain bridge isolated transmitter is a kind of differential signal (pressure, tension, gravity sensor equipment signals) isolation amplification, converted into proportional output DC signal isolation product, the pressure strain bridge isolated transmitter can provide a set of isolated high efficiency and high precision reference voltage source for pressure sensors. The small signal output of the synchronous sensor of the reference voltage source is provided for amplification, isolation and remote transmission. The product can provide a group of high-precision voltage source for pressure, tension, gravity sensor, the group of reference voltage source voltage is optional (5VDC\10VDC\12VDC), the differential signal isolation transmitter internal SMD process design and multi-channel efficient isolation power supply, so that the signal input (excitation voltage), working power supply, signal output between each other. Isolation voltage up to 3000VDC above, the differential transmitter adopts photoelectric isolation technology, compared with the magnetic electric isolation converter stronger anti-EMC electromagnetic interference and high-frequency signal interference characteristics, products are widely used in power, instrumentation, medical equipment, weighing instruments, industrial automation and other industrial fields. The product is the international standard DIN 35mm guide card slot fixed installation mode, user wiring can be used.JSD TAB-1001S series pressure strain bridge isolated transmitter is a kind of differential signal (pressure, tension, gravity sensor equipment signals) isolation amplification, converted into proportional output DC signal isolation product, the pressure strain bridge isolated transmitter can provide a set of isolated high efficiency and high precision reference voltage source for pressure sensors. The small signal output of the synchronous sensor of the reference voltage source is provided for amplification, isolation and remote transmission. The product can provide a group of high-precision voltage source for pressure, tension, gravity sensor, the group of reference voltage source voltage is optional (5VDC\10VDC\12VDC), the differential signal isolation transmitter internal SMD process design and multi-channel efficient isolation power supply, so that the signal input (excitation voltage), working power supply, signal output between each other. Isolation voltage up to 3000VDC above, the differential transmitter adopts photoelectric isolation technology, compared with the magnetic electric isolation converter stronger anti-EMC electromagnetic interference and high-frequency signal interference characteristics, products are widely used in power, instrumentation, medical equipment, weighing instruments, industrial automation and other industrial fields. The product is the international standard DIN 35mm guide card slot fixed installation mode, user wiring can be usedJSD TAB-1001S series pressure strain bridge isolated transmitter is a kind of differential signal (pressure, tension, gravity sensor equipment signals) isolation amplification, converted into proportional output DC signal isolation product, the pressure strain bridge isolated transmitter can provide a set of isolated high efficiency and high precision reference voltage source for pressure sensors. The small signal output of the synchronous sensor of the reference voltage source is provided for amplification, isolation and remote transmission. The product can provide a group of high-precision voltage source for pressure, tension, gravity sensor, the group of reference voltage source voltage is optional (5VDC\10VDC\12VDC), the differential signal isolation transmitter internal SMD process design and multi-channel efficient isolation power supply, so that the signal input (excitation voltage), working power supply, signal output between each other. Isolation voltage up to 3000VDC above, the differential transmitter adopts photoelectric isolation technology, compared with the magnetic electric isolation converter stronger anti-EMC electromagnetic interference and high-frequency signal interference characteristics, products are widely used in power, instrumentation, medical equipment, weighing instruments, industrial automation and other industrial fields. The product is the international standard DIN 35mm guide card slot fixed installation mode, user wiring can be used2mV/V to 0-10V Pressure strain bridge Isolation amplifier
Pressure strain bridge Isolation amplifier
MODEL:JSD TAB-1001S
Quotation is not final sale price, please consult sales manager for details
Shenzhen JieShengdaTechnology Co., Ltd.
Are there any special products that can be customized and developed
Exhibition hall: 
https://jieshengdakj.en.made-in-china.com/


JSD TAB-1001S series pressure strain bridge isolated transmitter is a kind of differential signal (pressure, tension, gravity sensor equipment signals) isolation amplification, converted into proportional output DC signal isolation product, the pressure strain bridge isolated transmitter can provide a set of isolated high efficiency and high precision reference voltage source for pressure sensors. The small signal output of the synchronous sensor of the reference voltage source is provided for amplification, isolation and remote transmission. The product can provide a group of high-precision voltage source for pressure, tension, gravity sensor, the group of reference voltage source voltage is optional (5VDC\10VDC\12VDC), the differential signal isolation transmitter internal SMD process design and multi-channel efficient isolation power supply, so that the signal input (excitation voltage), working power supply, signal output between each other. Isolation voltage up to 3000VDC above, the differential transmitter adopts photoelectric isolation technology, compared with the magnetic electric isolation converter stronger anti-EMC electromagnetic interference and high-frequency signal interference characteristics, products are widely used in power, instrumentation, medical equipment, weighing instruments, industrial automation and other industrial fields. The product is the international standard DIN 35mm guide card slot fixed installation mode, user wiring can be used.
Pressure strain bridge Isolation amplifier
MODEL:JSD TAB-1001S Series or JSD OI-Bx-Px-V(I)x  Series
Features:
low cost, small size, DIN35mm package with UL94-V0 flame retardant standard
Achieve Zero and gain adjustment by Adding multi-turn potentiometer
Three-port isolation (input, output and power supply)
Isolation voltage (3000VDC/60s)
Power supply:5V,12V,15V,24V
0~1mV/0~2mV/0~10mV/0~20mV/0~±10mV/0~±20mV/0~100mV Etc. differential voltage signal input, conversion and amplification
Converting the pressure, tension, gravity sensor signal into international standard current or voltage signals, such as 4-20mA/0-20mA/0-10V/1-5V/0-5V
Provides 5VDC ,10VDC or 12VDC reference voltage to the  Pressure-strain bridge  sensor
High accuracy:(0.1% F.S,0.2% F.S)
Full scale high linearity (non-linearity <0.1%)
strong anti-interference and Anti-high-frequency signal interference
Wide operation temperature (-45~+85 ºC)
Applications:
weighing sensor signal acquisition amplification and conversion
Analog signal ground interference suppression and signal isolation, acquisition and remote transmission
Industrial field signal remote transmission without distortion
non-power signal transmission
power isolation monitoring industrial field
Analog signal data isolation, acquisition and conversion
Industrial field signal isolation and conversion, and remote transmission without distortion
overcome EMC electromagnetic interference in industrial field
Various sensor interface match (acquisition, amplification, remote transmission)
Product Selection Parameter List:
 
Product Selection Parameter List:
Input Code Excitation voltage code Power supply code: Output Code
1:       1mV/V 1: 5VDC W: 8-40VDC 1: 4-20mA
2:      2mV/V 2: 10VDC 1: 24VDC 2: 0-20mA
3:      0-10mV 3: 12VDC 2: 15VDC 3: 0-10mA
4:      0-75mV     3: 12VDC 4: 0-5V
5:      0-100mV     4: 5VDC 5: 0-10V
6:      0-200mV         6: 1-5V
U: User-defined U: User-defined U: User-defined U: User-defined
Note:When ordering ,please determine input,output and power , special can customize
Selection Example:
Example 1: Signal input:2mV/V Excitation voltage:5VDC; output: 0-5V; power supply:5VDC; Model:JSD TAB-1001S-2144
Example 2:Signal input:0-20mV;output :4-20mA;power supply:24VDC;Model:JSD TAB-1001S-U11
Example 3:Signal input:0-100mV;output :0-20mA;power supply:24VDC;Model:JSD TAB-1001S-512
Signs Item Test condition Min Typ. Max Units
Isolation
characteristics
Isolation voltage AC,50Hz,tested for 1 minute, humidity<70%
leakage current < 1mA,)
  3000   V(rms)
Transmission characteristics Gain     1   mV/V
Gain drift     100   ppm/ºC
Non-linearity     0.1 0.2 %FSR
Input characteristics Input offset voltage     2 5 uV
Input impedance voltage   0.3 1  
Output characteristics Signal output voltage   0   10 V
current   0   20 mA
Load capacity voltage Vout=10V   2  
current   0 350 650 Ω
Frequency Response -3DB 1     KHz
Response Time     ≤ 1   mS
Signal output ripple Unfiltered   10 20 mVRMS
Signal voltage drift -45~+85ºC     0.2 mV/ºC
Power
Supply
input characteristics
Power supply voltage   5 12 40 VDC
Power loss     0.5 1 W
Range   -10   +10 %
             

Other characteristics
operating temperature   -45   85 ºC
storage temperature   -55   105 ºC
weight     65   g
Product Dimensions
 
  115*100*12.5 mm
Note: normal load≤350Ω,if requiring load is 650Ω, Please note when ordering
 
 
Pin Function Description:
 
Signal types Pin Function Pin Function storage
Voltage
(Current)
in/out
1 Power supply In + 5 Signal Input+   Standard DIN35
Rail
 mounting
2 Power supply In - 6 Signal Input-
3 Signal Output + 7 Excitation Voltage +
4 Signal Output - 8 citation Voltage -
Notes:
1,Please read the user manual carefully before using. If any question please contact our technical support department.
2,Please do not use this product in hazardous area.
3,NC" pin must not be connected to any external circuit, otherwise it will damage the product itself;
4,Calculating from the date of delivery, during normal use of the product, any quality problems are free repair or replacement by Company during 3 years warranty;
5,the product is strictly forbidden demolish without permission for not damage;
6,All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
7,In this datasheet, all the test methods of indications are based on corporate standards.
 
Copyright:
Copyright © 2018 Shenzhen Jieshengda Technology Co., Ltd.
Without the prior written permission of the company, any content in this manual may not be copied, distributed, translated or transmitted in any form or method (electronic or mechanical).
Including photocopying, recording or storage in any information storage and retrieval system. This manual is subject to modification or update without notice.
Jieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation AmplifierJieshengda Jsd Tab-1001s 2mv/V to 0-10V Pressure Strain Bridge Analog Current Voltage Signal Isolation Amplifier

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier